Your browser doesn't support javascript.
loading
Impact of prospective motion correction, distortion correction methods and large vein bias on the spatial accuracy of cortical laminar fMRI at 9.4 Tesla.
Bause, Jonas; Polimeni, Jonathan R; Stelzer, Johannes; In, Myung-Ho; Ehses, Philipp; Kraemer-Fernandez, Pablo; Aghaeifar, Ali; Lacosse, Eric; Pohmann, Rolf; Scheffler, Klaus.
Afiliação
  • Bause J; Department for Biomedical Magnetic Resonance Imaging, University Hospital Tuebingen, Germany; High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tuebingen, Germany; Graduate School of Neuronal and Behavioral Sciences, University of Tuebingen, Tuebingen, Germany. E
  • Polimeni JR; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Harvard Medical School, Massachusetts General Hospital, Charleston, MA, USA; Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA, USA.
  • Stelzer J; Department for Biomedical Magnetic Resonance Imaging, University Hospital Tuebingen, Germany; High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tuebingen, Germany.
  • In MH; Department of Radiology, Mayo Clinic, Rochester, MN, USA.
  • Ehses P; German Center for Neurodegenerative Diseases (DZNE), Bonn, Germany.
  • Kraemer-Fernandez P; Department of Prosthodontics, University Hospital Tuebingen, Tuebingen, Germany.
  • Aghaeifar A; High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tuebingen, Germany; Graduate School of Neuronal and Behavioral Sciences, University of Tuebingen, Tuebingen, Germany.
  • Lacosse E; High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tuebingen, Germany; Autonomous Learning Group, Max-Planck Institute for Intelligent Systems, Tuebingen, Germany.
  • Pohmann R; High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tuebingen, Germany.
  • Scheffler K; Department for Biomedical Magnetic Resonance Imaging, University Hospital Tuebingen, Germany; High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tuebingen, Germany.
Neuroimage ; 208: 116434, 2020 03.
Article em En | MEDLINE | ID: mdl-31812715

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Cerebrais / Processamento de Imagem Assistida por Computador / Córtex Cerebral / Imagem Ecoplanar / Neuroimagem Funcional Limite: Adult / Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Cerebrais / Processamento de Imagem Assistida por Computador / Córtex Cerebral / Imagem Ecoplanar / Neuroimagem Funcional Limite: Adult / Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article