Your browser doesn't support javascript.
loading
Oligonucleotide quantification and metabolite profiling by high-resolution and accurate mass spectrometry.
Liu, Ju; Li, Jing; Tran, Chris; Aluri, Krishna; Zhang, Xuemei; Clausen, Valerie; Zlatev, Ivan; Guan, Lihua; Chong, Saeho; Charisse, Klaus; Wu, Jing-Tao; Najarian, Diana; Xu, Yuanxin.
Afiliação
  • Liu J; Alnylam Pharmaceuticals Inc., Cambridge, MA 02142, USA.
  • Li J; Alnylam Pharmaceuticals Inc., Cambridge, MA 02142, USA.
  • Tran C; Alnylam Pharmaceuticals Inc., Cambridge, MA 02142, USA.
  • Aluri K; Alnylam Pharmaceuticals Inc., Cambridge, MA 02142, USA.
  • Zhang X; Alnylam Pharmaceuticals Inc., Cambridge, MA 02142, USA.
  • Clausen V; Alnylam Pharmaceuticals Inc., Cambridge, MA 02142, USA.
  • Zlatev I; Alnylam Pharmaceuticals Inc., Cambridge, MA 02142, USA.
  • Guan L; Alnylam Pharmaceuticals Inc., Cambridge, MA 02142, USA.
  • Chong S; Alnylam Pharmaceuticals Inc., Cambridge, MA 02142, USA.
  • Charisse K; Alnylam Pharmaceuticals Inc., Cambridge, MA 02142, USA.
  • Wu JT; Alnylam Pharmaceuticals Inc., Cambridge, MA 02142, USA.
  • Najarian D; Alnylam Pharmaceuticals Inc., Cambridge, MA 02142, USA.
  • Xu Y; Alnylam Pharmaceuticals Inc., Cambridge, MA 02142, USA.
Bioanalysis ; 11(21): 1967-1980, 2019 Nov.
Article em En | MEDLINE | ID: mdl-31829056
ABSTRACT

Aim:

Advancements in RNA interference therapeutics have triggered development of improved bioanalytical methods for oligonucleotide metabolite profiling and high-throughput quantification in biological matrices. Results &

methodology:

HPLC coupled with high-resolution mass spectrometry (LC-HRMS) methods were developed to investigate the metabolism of a REVERSIR™ molecule in vivo. Plasma and tissue samples were extracted using solid-phase extraction followed by LC-HRMS analysis for metabolite profiling and quantification. The method was qualified from 10 to 5000 ng/ml (plasma) and 100 to 50000 ng/g (liver and kidney). In rat liver, intra and interday accuracy ranged from 80.9 to 118.5% and 88.4 to 111.9%, respectively, with acceptable precision (<20% CV).

Conclusion:

The LC-HRMS method can be applied for metabolite profiling and quantification of oligonucleotides in biological matrices.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oligonucleotídeos / Espectrometria de Massas / Metabolômica Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oligonucleotídeos / Espectrometria de Massas / Metabolômica Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article