Your browser doesn't support javascript.
loading
Development of a molecularly imprinted polymer electrochemical sensor and its application for sensitive detection and determination of malathion in olive fruits and oils.
Aghoutane, Youssra; Diouf, Alassane; Österlund, Lars; Bouchikhi, Benachir; El Bari, Nezha.
Afiliação
  • Aghoutane Y; Biotechnology Agroalimentary and Biomedical Analysis Group, Department of Biology, Faculty of Sciences, Moulay Ismaïl University, B.P. 11201, Zitoune, Meknes, Morocco; Sensor Electronic & Instrumentation Group, Department of Physics, Faculty of Sciences, Moulay Ismaïl University, B.P. 11201, Zit
  • Diouf A; Biotechnology Agroalimentary and Biomedical Analysis Group, Department of Biology, Faculty of Sciences, Moulay Ismaïl University, B.P. 11201, Zitoune, Meknes, Morocco; Sensor Electronic & Instrumentation Group, Department of Physics, Faculty of Sciences, Moulay Ismaïl University, B.P. 11201, Zit
  • Österlund L; Dept. Engineering Sciences, The Ångström Laboratory, Uppsala University, P. O. Box 534, SE-75121 Uppsala, Sweden.
  • Bouchikhi B; Sensor Electronic & Instrumentation Group, Department of Physics, Faculty of Sciences, Moulay Ismaïl University, B.P. 11201, Zitoune, Meknes, Morocco.
  • El Bari N; Biotechnology Agroalimentary and Biomedical Analysis Group, Department of Biology, Faculty of Sciences, Moulay Ismaïl University, B.P. 11201, Zitoune, Meknes, Morocco. Electronic address: n_elbari@hotmail.com.
Bioelectrochemistry ; 132: 107404, 2020 Apr.
Article em En | MEDLINE | ID: mdl-31911357
ABSTRACT
Malathion (MAL) is an organophosphorus (OP) insecticide. It is a cholinesterase inhibitor, which can pose serious health and environmental problems. In this study, a sensitive and selective molecular imprinted polymer (MIP) based on screen-printed gold electrodes (Au-SPE) for MAL detection in olive oils and fruits, was devised. The MIP sensor was prepared using acrylamide as the functional monomer and MAL as the template. Subsequently, the morphology of the electrode surface was studied by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The electrochemical characterization of the developed MIP sensor was performed by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS) techniques. The operational repeatability and stability of the sensor were studied. It was found to have a dynamic concentration range of (0.1 pg mL-1-1000 pg mL-1) and a low limit of detection (LOD) of 0.06 pg mL-1. Furthermore, the sensor was employed to determine MAL content in olive oil with a recovery rate of 87.9% and a relative standard deviation of 8%. It was successfully applied for MAL determination in real samples and promise to open new opportunities for the detection of OP pesticides residues in various food products, as well as in environmental applications.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Contaminação de Alimentos / Olea / Impressão Molecular / Técnicas Eletroquímicas / Azeite de Oliva / Inseticidas / Malation Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Contaminação de Alimentos / Olea / Impressão Molecular / Técnicas Eletroquímicas / Azeite de Oliva / Inseticidas / Malation Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2020 Tipo de documento: Article