Your browser doesn't support javascript.
loading
A review of sample thickness effects on high-resolution transmission electron microscopy imaging.
Li, Shouqing; Chang, Yunjie; Wang, Yumei; Xu, Qiang; Ge, Binghui.
Afiliação
  • Li S; Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China; University of Chinese Academy of Sciences, Beijing 100049, China.
  • Chang Y; Department of Microbial Pathogenesis, Yale University School of Medicine, New Haven, CT 06511, United States; Microbial Sciences Institute, Yale University, West Haven, CT 06516, United States.
  • Wang Y; Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China.
  • Xu Q; Nanodim-GZ, Guangzhou 510290, China.
  • Ge B; Institutes of Physical Science and Information Technology, Anhui University, Hefei 230601, China; Key Laboratory of Structure and Functional Regulation of Hybrid Material (Anhui University), Ministry of Education, Hefei 230601, China. Electronic address: bhge@ahu.edu.cn.
Micron ; 130: 102813, 2020 03.
Article em En | MEDLINE | ID: mdl-31927411
ABSTRACT
High-resolution transmission electron microscopy (HRTEM) is an important approach to analyzing material structures. However, in reality, preparing a sufficiently thin sample for use in HRTEM, based on which images could be interpreted by weak phase object approximation theory, is difficult. During the imaging process, the thickness of the sample has two primary effects-a dynamical effect and a non-linear effect. Both are reviewed in this paper. Considering only the dynamical effect, the Bloch wave method and multislice theory have been proposed to understand the relationship between sample thickness and imaging. These methods exhibit high accuracy but high complexity as well. Sacrificing accuracy, pseudo-weak phase object approximation (PWPOA) theory can provide clues to the relationship in reciprocal space with greater simplicity. Meanwhile, in real space, channeling theory describes the dynamical effect with sufficient accuracy, and with the 1s state approximation, i.e., for a certain range of thicknesses, it provides a physical image and simplified expression with which to describe the relationship between the exit wave and sample thickness. As for the non-linear effect, a method of separating linear and non-linear information using a combination of transmission cross-coefficient theory and PWPOA theory was recently proposed. The variation of non-linear and linear imaging with sample thickness has also been discussed. A deep understanding has been acquired regarding the effects of the sample thickness, but a complete understanding of the HRTEM imaging process for thick samples has remained elusive. This understanding is crucial to the retrieval of structure from HRTEM images.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Microscopia Eletrônica de Transmissão Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Microscopia Eletrônica de Transmissão Idioma: En Ano de publicação: 2020 Tipo de documento: Article