Your browser doesn't support javascript.
loading
Advancing Liquid Atmospheric Pressure Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Toward Ultrahigh-Throughput Analysis.
Krenkel, Henriette; Hartmane, Evita; Piras, Cristian; Brown, Jeffery; Morris, Michael; Cramer, Rainer.
Afiliação
  • Krenkel H; Department of Chemistry , University of Reading , Whiteknights , Reading RG6 6AD , United Kingdom.
  • Hartmane E; Department of Chemistry , University of Reading , Whiteknights , Reading RG6 6AD , United Kingdom.
  • Piras C; Department of Chemistry , University of Reading , Whiteknights , Reading RG6 6AD , United Kingdom.
  • Brown J; Department of Chemistry , University of Reading , Whiteknights , Reading RG6 6AD , United Kingdom.
  • Morris M; Waters Corporation , Stamford Avenue , Wilmslow SK9 4AX , United Kingdom.
  • Cramer R; Waters Corporation , Stamford Avenue , Wilmslow SK9 4AX , United Kingdom.
Anal Chem ; 92(4): 2931-2936, 2020 02 18.
Article em En | MEDLINE | ID: mdl-31967792
ABSTRACT
Label-free high-throughput screening using mass spectrometry has the potential to provide rapid large-scale sample analysis at a speed of more than one sample per second. Such speed is important for compound library, assay and future clinical screening of millions of samples within a reasonable time frame. Herein, we present a liquid atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) setup for high-throughput large-scale sample analysis (>5 samples per second) for three substance classes (peptides, antibiotics, and lipids). Liquid support matrices (LSM) were used for the analysis of standard substances as well as complex biological fluids (milk). Throughput and analytical robustness were mainly dependent on the complexity of the sample composition and the current limitations of the commercial hardware. However, the ultimate limits of liquid AP-MALDI in sample throughput can be conservatively estimated to be beyond 10-20 samples per second. This level of analytical speed is highly competitive compared with other label-free MS methods, including electrospray ionization and solid state MALDI, as well as MS methods using multiplexing by labeling, which in principle can also be used in combination with liquid AP-MALDI MS.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article