Evaluating body composition in infancy and childhood: A comparison between 4C, QMR, DXA, and ADP.
Heard-Lipsmeyer, Melissa E; Hull, Holly; Sims, Clark R; Cleves, Mario A; Andres, Aline.
Afiliação
  • Heard-Lipsmeyer ME; Arkansas Children's Nutrition Center, University of Arkansas for Medical Sciences, Little Rock, Arkansas.
  • Hull H; Department of Pediatrics, University of Arkansas for Medical Sciences, Little Rock, Arkansas.
  • Sims CR; Division of Cell Biology and Physiology, Edward Via College of Osteopathic Medicine-Louisiana Campus, Monroe, Louisiana.
  • Cleves MA; Department of Dietetics and Nutrition, University of Kansas Medical Center, Kansas City, Kansas.
  • Andres A; Arkansas Children's Nutrition Center, University of Arkansas for Medical Sciences, Little Rock, Arkansas.
Pediatr Obes ; 15(6): e12617, 2020 06.
Article em En | MEDLINE | ID: mdl-31986239
ABSTRACT

BACKGROUND:

Accurate and precise methods to measure of body composition in infancy and childhood are needed.

OBJECTIVES:

This study evaluated differences and precision of three methods when compared with the four-compartment (4C) model for estimating fat mass (FM).

METHODS:

FM of children (age 14 days to 6 years of age, N = 346) was obtained using quantitative nuclear magnetic resonance (QMR, EchoMRI-AH), air-displacement plethysmography (ADP, PeaPod, less than or equal to 8 kg, BodPod age 6 years or older), and dual-energy X-ray absorptiometry (DXA, Hologic QDR). The 4C model was computed. Correlation, concordance, and Bland-Altman analyses were performed.

RESULTS:

In infants, PeaPod had high individual FM accuracy, whereas DXA had high group FM accuracy compared with 4C. In children, DXA had high group and individual FM accuracies compared with 4C. QMR underestimated group FM in infants and children (300 and 510 g, respectively). The instrument FM precision was best for QMR (10 g) followed by BodPod (34 g), PeaPod (38 g), and DXA (45 g).

CONCLUSIONS:

In infants, PeaPod was the best method to estimate individual FM whereas DXA was best to estimate group FM. In children, DXA was best to estimate individual and group FM. QMR had the highest instrument precision.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pletismografia / Composição Corporal / Espectroscopia de Ressonância Magnética / Absorciometria de Fóton / Tecido Adiposo Limite: Child / Child, preschool / Female / Humans / Infant / Male / Newborn Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pletismografia / Composição Corporal / Espectroscopia de Ressonância Magnética / Absorciometria de Fóton / Tecido Adiposo Limite: Child / Child, preschool / Female / Humans / Infant / Male / Newborn Idioma: En Ano de publicação: 2020 Tipo de documento: Article