Your browser doesn't support javascript.
loading
Online sample clean-up and enrichment of proteins from salty media with dynamic double gradients on a paper fluidic channel.
Cai, Yu; Niu, Ji-Cheng; Liu, Yu-Qi; Du, Xin-Li; Wu, Zhi-Yong.
Afiliação
  • Cai Y; Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China.
  • Niu JC; Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China.
  • Liu YQ; Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China.
  • Du XL; Liaoning Diabetes Treatment Center, Shenyang, 110015, China.
  • Wu ZY; Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China. Electronic address: zywu@mail.neu.edu.cn.
Anal Chim Acta ; 1100: 149-155, 2020 Mar 01.
Article em En | MEDLINE | ID: mdl-31987135
ABSTRACT
Paper-based analytical device (PAD) has received more and more attention in the field of point-of-care test (POCT) due to its low cost, portability and simple operation. Sensitivity and selectivity are two important aspects in clinical diagnostic analysis. However, low sensitivity of a PAD limits its wider application for POCT. Here we introduced a PAD that can clean and enrich the protein content from salty media with both electric field (E) and pH gradient (double E/pH gradients), with which 100-fold enrichment effect could be achieved within 70 s as demonstrated by fluorescein isothiocyanate labeled bovine serum albumin (FITC-BSA) from artificial urine media. With post staining of the protein stacking band with bromophenol blue (BPB), selective colorimetric detection of human serum albumin (HSA) was achieved simply with smartphone camera in the clinically significant range of 10-300 mg‧L-1 (R2 = 0.99) with a limit of detection (LOD) of 4.9 mg‧L-1. Detection of microalbuminuria (MAU) of diabetic patients was demonstrated with this method without difference (ɑ = 0.01) to that by the clinical method (immunoturbidimetry). This work demonstrated the potential of this PAD method in online sample pretreatment and detection of target component from complex physiological samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Papel / Soroalbumina Bovina / Técnicas Analíticas Microfluídicas / Smartphone / Albumina Sérica Humana Tipo de estudo: Diagnostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Papel / Soroalbumina Bovina / Técnicas Analíticas Microfluídicas / Smartphone / Albumina Sérica Humana Tipo de estudo: Diagnostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article