Your browser doesn't support javascript.
loading
Enhancing Data Reliability in TOMAHAQ for Large-Scale Protein Quantification.
Liu, Fang; Singhal, Kratika; Matney, Rowan; Acharya, Swati; Akdis, Cezmi A; Nadeau, Kari C; Chien, Allis S; Leib, Ryan D.
Afiliação
  • Liu F; Vincent Coates Foundation Mass Spectrometry Laboratory, Stanford University, Stanford, CA, 94305, USA.
  • Singhal K; Vincent Coates Foundation Mass Spectrometry Laboratory, Stanford University, Stanford, CA, 94305, USA.
  • Matney R; Vincent Coates Foundation Mass Spectrometry Laboratory, Stanford University, Stanford, CA, 94305, USA.
  • Acharya S; Sean Parker Center, Stanford University School of Medicine, Stanford, CA, 94305, USA.
  • Akdis CA; Swiss Institute of Allergy and Asthma Research, University of Zurich, Davos Platz, CH-7270, Switzerland.
  • Nadeau KC; Sean Parker Center, Stanford University School of Medicine, Stanford, CA, 94305, USA.
  • Chien AS; Vincent Coates Foundation Mass Spectrometry Laboratory, Stanford University, Stanford, CA, 94305, USA.
  • Leib RD; Vincent Coates Foundation Mass Spectrometry Laboratory, Stanford University, Stanford, CA, 94305, USA.
Proteomics ; 20(11): e1900105, 2020 06.
Article em En | MEDLINE | ID: mdl-32032464
ABSTRACT
The analytical scale of most mass-spectrometry-based targeted proteomics assays is usually limited by assay performance and instrument utilization. A recently introduced method, called triggered by offset, multiplexed, accurate mass, high resolution, and absolute quantitation (TOMAHAQ), combines both peptide and sample multiplexing to simultaneously improve analytical scale and quantitative performance. In the present work, critical technical requirements and data analysis considerations for successful implementation of the TOMAHAQ technique based on the study of a total of 185 target peptides across over 200 clinical plasma samples are discussed. Importantly, it is observed that significant interference originate from the TMTzero reporter ion used for the synthetic trigger peptides. This interference is not expected because only TMT10plex reporter ions from the target peptides should be observed under typical TOMAHAQ conditions. In order to unlock the great promise of the technique for high throughput quantification, here a post-acquisition data correction strategy to deconvolute the reporter ion superposition and recover reliable data is proposed.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Proteômica Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Proteômica Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article