Your browser doesn't support javascript.
loading
Novel Technique for C1-2 Interlaminar Arthrodesis Utilizing a Modified Sonntag Loop-Suture Graft With Posterior C1-2 Fixation.
Koffie, Robert M; Larsen, Alexandra M Giantini; Grannan, Benjamin L; Hadzipasic, Muhamed; Yanamadala, Vijay; Beaver, Laura Van; Shankar, Ganesh M; Shin, John H.
Afiliação
  • Koffie RM; Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
  • Larsen AMG; Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
  • Grannan BL; Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
  • Hadzipasic M; Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
  • Yanamadala V; Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
  • Beaver LV; Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
  • Shankar GM; Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
  • Shin JH; Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
Neurospine ; 17(3): 659-665, 2020 Sep.
Article em En | MEDLINE | ID: mdl-32054143
ABSTRACT

OBJECTIVE:

Conventional techniques for atlantoaxial fixation and fusion typically pass cables or wires underneath C1 lamina to secure the bone graft between the posterior elements of C1-2, which leads to complications such as cerebrospinal fluid (CSF) leak and neurological injury. With the evolution of fixation hardware, we propose a novel C1-2 fixation technique that avoids the morbidity and complications associated with sublaminar cables and wires.

METHODS:

This technique entails wedging and anchoring a structural iliac crest graft between C1 and C2 for interlaminar arthrodesis and securing it using a 0-Prolene suture at the time of C1 lateral mass and C2 pars interarticularis screw fixation.

RESULTS:

We identified 32 patients who underwent surgery for atlantoaxial with our technique. A 60% improvement in pain-related disability from preoperative baseline was demonstrated by Neck Disability Index (p < 0.001). There were no neurologic deficits. Complications included 2 patients CSF leaks related to presenting trauma, 1 patient with surgical site infection, and 1 patient with transient dysphagia. The rate of radiographic atlantoaxial fusion was 96.8% at 6 months, with no evidence of instrumentation failure, graft dislodgement, or graft related complications.

CONCLUSION:

We demonstrate a novel technique for C1-2 arthrodesis that is a safe and effective option for atlantoaxial fusion.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article