Your browser doesn't support javascript.
loading
Inter-rater and intra-rater reliability of the extended TUG test in elderly participants.
Bedoya-Belmonte, Juan José; Rodríguez-González, María Del Mar; González-Sánchez, Manuel; Pitarch, Jose Miguel Barreda; Galán-Mercant, Alejandro; Cuesta-Vargas, Antonio I.
Afiliação
  • Bedoya-Belmonte JJ; Servicio Andaluz de Salud, Distrito Malaga, CS tiro pichón, Málaga, Spain.
  • Rodríguez-González MDM; Servicio Andaluz de Salud, Distrito Malaga, CS tiro pichón, Málaga, Spain.
  • González-Sánchez M; Departamento de Fisioterapia, Grupo de Clinimetría (F-14), Facultad de Ciencias de la Salud, Instituto de Biomedicina de Málaga (IBIMA), Andalucía Tech, Universidad de Málaga, Arquitecto Francisco Peñalosa s/n. (ampliación Campus Teatinos), 29071, Málaga, Spain. mgsa23@uma.es.
  • Pitarch JMB; Departamento de Ciencias de la Salud, Facultad de Ciencias de la Salud, Universidad de Jaén, Jaén, Spain.
  • Galán-Mercant A; Departamento de Fisioterapia; Facultad de Enfermería y Fisioterapia, Universidad de Cádiz, Cádiz, Spain.
  • Cuesta-Vargas AI; Departamento de Fisioterapia, Grupo de Clinimetría (F-14), Facultad de Ciencias de la Salud, Instituto de Biomedicina de Málaga (IBIMA), Andalucía Tech, Universidad de Málaga, Arquitecto Francisco Peñalosa s/n. (ampliación Campus Teatinos), 29071, Málaga, Spain.
BMC Geriatr ; 20(1): 56, 2020 02 13.
Article em En | MEDLINE | ID: mdl-32054448
BACKGROUND: To analyse the reliability, variance and execution time of the Extended Timed Up and Go (Extended TUG) test in three age groups of elderly participants (G1: 55-64 years; G2: 65-74 years; G3: 75-85 years). METHODS: An analytical cross-sectional study of 114 recruited participants (63 women) of average age 70.17 (± 7.3) years was undertaken. Each participant performed the Extended TUG three consecutive times, with a rest break between tests of 120 s. Both the intragroup and intergroup reliability of the measurements in the Extended TUG were analysed. RESULTS: The reliability of the Extended TUG test is excellent for the first and second decades but drops down to good for the third decade. Specifically, intragroup reliability ranged from 0.784 for G3 to 0.977 for G1 (G2 = 0.858). Intergroup reliability, compared with intragroup reliability, was slightly lower, ranging between 0.779 for G3 and 0.972 for G1 (G2 = 0.853). CONCLUSION: The reliability of the Extended TUG test progressively decreases with increasing age, being excellent for the younger age groups and good for the oldest age group.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Modalidades de Fisioterapia Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Modalidades de Fisioterapia Tipo de estudo: Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article