Your browser doesn't support javascript.
loading
Performance and cutoffs for liver fibrosis staging of a two-dimensional shear wave elastography technique.
Ferraioli, Giovanna; Maiocchi, Laura; Dellafiore, Carolina; Tinelli, Carmine; Above, Elisabetta; Filice, Carlo.
Afiliação
  • Ferraioli G; Dipartimento di Scienze Clinico-Chirurgiche, Diagnostiche e Pediatriche, Medical School University of Pavia.
  • Maiocchi L; Clinical Sciences and Infectious Diseases Department.
  • Dellafiore C; Clinical Sciences and Infectious Diseases Department.
  • Tinelli C; Dipartimento di Scienze Clinico-Chirurgiche, Diagnostiche e Pediatriche, Medical School University of Pavia.
  • Above E; Clinical Sciences and Infectious Diseases Department.
  • Filice C; Biometric Unit, Fondazione IRCCS Policlinico S. Matteo, Pavia, Italy.
Eur J Gastroenterol Hepatol ; 33(1): 89-95, 2021 01.
Article em En | MEDLINE | ID: mdl-32118850
ABSTRACT

OBJECTIVES:

To assess performance and cutoffs of the 2-dimensional shear wave elastography technique available on the Aplio i800 ultrasound system (Canon Medical Systems, Japan), using transient elastography as reference standard, and to assess the correlation of shear-wave-speed dispersion with liver fibrosis or steatosis.

METHODS:

This was a single-center cross-sectional study. The correlations between values obtained with transient elastography and 2-dimensional-shear wave elastography, and between shear-wave-speed dispersion and fibrosis or steatosis, were assessed with Pearson's r. The diagnostic performance of the 2-dimensional-shear wave elastography for staging significant fibrosis and severe fibrosis compared to transient elastography was assessed using the area under the receiver operating characteristic curve analysis.

RESULTS:

Three hundred sixty-seven patients (198 males and 169 females) were studied. There was a high correlation between 2-dimensional-shear wave elastography and transient elastography (r = 0.87, P < 0.0001). The area under the receiver operating characteristics of 2-dimensional-shear wave elastography for staging significant fibrosis (F2) and severe fibrosis (F3-F4), respectively, were 0.97 (95% confidence interval, 0.91-0.98) and 0.97 (95% confidence interval, 0.95-0.99). The best cutoffs for significant fibrosis and severe fibrosis, respectively, were > 7 and > 9 kPa. Shear-wave-speed dispersion showed a high correlation with fibrosis (r = 0.85, P < 0.0001), whereas there was a very weak correlation with steatosis.

CONCLUSIONS:

The results of this study show that this 2-dimensional-shear wave elastography technique is accurate for staging liver fibrosis. Shear-wave-speed dispersion is highly correlated with liver fibrosis but not with steatosis.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas de Imagem por Elasticidade Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male País/Região como assunto: Asia Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas de Imagem por Elasticidade Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male País/Região como assunto: Asia Idioma: En Ano de publicação: 2021 Tipo de documento: Article