Your browser doesn't support javascript.
loading
PATIENT-SPECIFIC DOSIMETRY USING IN-HOUSE DEVELOPED OSL DISC DOSEMETERS.
Kumar, Pradip; Sharma, Sunil Dutt; Dhabekar, Bhushan; Mishra, Devesh Ramdhar; Rawat, Narender Singh; Kadam, Sonal; Chaudhari, Suresh; Chandola, Rakesh Mohan; Agrawal, Sadhana.
Afiliação
  • Kumar P; National Institute of Technology, Raipur, Chhattisgarh, India.
  • Sharma SD; Atomic Energy Regulatory Board, Mumbai, Maharashtra, India.
  • Dhabekar B; Bhabha Atomic Research Centre, Mumbai, Maharashtra, India.
  • Mishra DR; Homi Bhabha National Institute, Mumbai, Maharashtra, India.
  • Rawat NS; Bhabha Atomic Research Centre, Mumbai, Maharashtra, India.
  • Kadam S; Homi Bhabha National Institute, Mumbai, Maharashtra, India.
  • Chaudhari S; Bhabha Atomic Research Centre, Mumbai, Maharashtra, India.
  • Chandola RM; Homi Bhabha National Institute, Mumbai, Maharashtra, India.
  • Agrawal S; Bhabha Atomic Research Centre, Mumbai, Maharashtra, India.
Radiat Prot Dosimetry ; 189(1): 127-135, 2020 Jul 07.
Article em En | MEDLINE | ID: mdl-32140728
ABSTRACT
Circular discs of diameter 5 mm were made from three indigenously developed optically stimulated luminescent (OSL) phosphors for medical dosimetry. Dosimetric characteristics of these discs were evaluated for their use in machine and patient-specific dosimetry in radiotherapy. Uncertainty in dosimetric measurements using these discs was also estimated, and combined standard uncertainty in measurement of absorbed dose was found to be 3.34%. Characterisation studies indicate that OSL discs are suitable for dosimetric application in radiotherapy. These discs were also used for patient-specific dosimetry in conventional and conformal radiotherapy treatments (five different cases) vis-à-vis ionisation chamber and Gafchromic EBT3 film. Doses measured by OSL discs were found comparable to ionisation chamber and Gafchromic EBT3 film measured values and radiotherapy treatment planning system (TPS) calculated dose values in all the cases. The variation between TPS calculated dose values and OSL discs measured dose values was found within the measurement uncertainty.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria / Dosimetria Fotográfica Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria / Dosimetria Fotográfica Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article