Your browser doesn't support javascript.
loading
Evaluation of a smart activatable MRI nanoprobe to target matrix metalloproteinases in the early-stages of abdominal aortic aneurysms.
Yao, Yuyu; Cheng, Kai; Cheng, Zhen.
Afiliação
  • Yao Y; Department of Cardiology, Zhongda Hospital, Medical School of Southeast University, Nanjing, Jiangsu, China; Molecular Imaging Program at Stanford (MIPS), Department of Radiology and Bio-X Program, Stanford University School of Medicine, Stanford, CA, USA.
  • Cheng K; Molecular Imaging Program at Stanford (MIPS), Department of Radiology and Bio-X Program, Stanford University School of Medicine, Stanford, CA, USA.
  • Cheng Z; Molecular Imaging Program at Stanford (MIPS), Department of Radiology and Bio-X Program, Stanford University School of Medicine, Stanford, CA, USA. Electronic address: zcheng@stanford.edu.
Nanomedicine ; 26: 102177, 2020 06.
Article em En | MEDLINE | ID: mdl-32142755
ABSTRACT
Matrix metalloproteinases (MMPs) activation contributes to abdominal aortic aneurysm (AAA) growth and rupture. The study was to evaluate the ability of a novel activatable magnetic resonance imaging (MRI) nanoprobe, to target MMPs in an Angiotensin II (ANG II)-induced AAA model. The activatable nanoprobe is composed of a hydrophilic polyethylene glycol coating layer immobilized on the external surface of core/shell Fe/iron oxide nanoparticles; between them, there was grafted the MMP peptide substrate. In the ANG II infusion mice model of AAAs, MRI was performed to characterize the progression of model. The contrast-to-noise ratio was lower in the aneurysm of the mice injected with activatable nanoprobe. Histological studies revealed the presence of MMPs and iron-oxide in regions of MR signal decrease. MRI combined with nanoprobe allows the detection of MMP activity within the wall of AAA, thus representing a potential noninvasive method to predict the rupture risk of AAA.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Aneurisma da Aorta Abdominal / Metaloproteinases da Matriz / Nanopartículas Tipo de estudo: Prognostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Aneurisma da Aorta Abdominal / Metaloproteinases da Matriz / Nanopartículas Tipo de estudo: Prognostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article