Your browser doesn't support javascript.
loading
Feasibility study of the Fricke chemical dosimeter as an independent dosimetric system for the small animal radiation research platform (SARRP).
Muñoz Arango, Erika; Pickler, Arissa; Mantuano, Andrea; Salata, Camila; de Almeida, Carlos Eduardo.
Afiliação
  • Muñoz Arango E; Departamento de Ciências Radiológicas DCR, Universidade do Estado do Rio de Janeiro (UERJ), RJ, Rio de Janeiro, Brazil. Electronic address: munozare@gmail.com.
  • Pickler A; Departamento de Ciências Radiológicas DCR, Universidade do Estado do Rio de Janeiro (UERJ), RJ, Rio de Janeiro, Brazil.
  • Mantuano A; Departamento de Ciências Radiológicas DCR, Universidade do Estado do Rio de Janeiro (UERJ), RJ, Rio de Janeiro, Brazil.
  • Salata C; Departamento de Ciências Radiológicas DCR, Universidade do Estado do Rio de Janeiro (UERJ), RJ, Rio de Janeiro, Brazil; Brazilian Nuclear Energy Commission, CNEN, RJ, Rio de Janeiro, Brazil.
  • de Almeida CE; Departamento de Ciências Radiológicas DCR, Universidade do Estado do Rio de Janeiro (UERJ), RJ, Rio de Janeiro, Brazil.
Phys Med ; 71: 168-175, 2020 Mar.
Article em En | MEDLINE | ID: mdl-32163885
ABSTRACT
For the small animal radiation research platform (SARRP) with X-ray beams in the medium energy range (tube operating voltage at 220 kVp), reference dosimetry is based on the AAPM TG-61 recommendations following the in-phantom method. The objective of this study was to evaluate the feasibility of the Fricke solution as a dosimeter to determine the absorbed dose to water. Feasibility studies at this X-ray energy range are not widely available. We evaluated the accuracy, dose linearity and dose rate dependence in a comparison with an NE 2571 Farmer ionization chamber (IC) and measurements in water. The G(Fe3+) factor was calculated from the curve fitting of the chemical yields for two radioactive sources (192Ir and 60Co) and one X-ray system with a tube operating at 150 and 250 kVp. The same methodology was followed for the dependence of the G(Fe3+) value on the energy and the dose agreement assessment for 180 and 200 kVp in the SARRP. The Fricke system exhibits a good linear response over the range of 5-70 Gy and an accuracy better than 2% for a 2 Gy/min dose rate. The dose rate dependence is smaller than 1% for dose rates greater than 1 Gy/min. The dependence of the G(Fe3+) value on the energy is smaller than 0.41%, with dose agreements better than 2%. The feasibility of the dosimeter for measurements at high doses and high dose rates makes it a suitable tool for dosimetric verifications in several preclinical irradiation configurations.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2020 Tipo de documento: Article