Your browser doesn't support javascript.
loading
Effect of geometrical parameters on the fluid dynamics of air-powered needle-free jet injectors.
Mohizin, Abdul; Kim, Jung Kyung.
Afiliação
  • Mohizin A; Department of Mechanical Engineering, Graduate School, Kookmin University, Seoul, 02707, Republic of Korea.
  • Kim JK; School of Mechanical Engineering and Department of Integrative Biomedical Science and Engineering, Graduate School, Kookmin University, Seoul, 02707, Republic of Korea. Electronic address: jkkim@kookmin.ac.kr.
Comput Biol Med ; 118: 103642, 2020 03.
Article em En | MEDLINE | ID: mdl-32174321
Needle-free jet injectors are non-invasive systems having intradermal drug delivery capabilities. At present, they revolutionize the next phase of drug delivery and therapeutic applications in the medical industry. An efficiently designed injection chamber can reduce the energy consumption required to achieve the maximum penetration depth in skin tissue. In this study, the authors explored the effect of various geometrical parameters using a computational fluid dynamics tool. Peak stagnation pressure during the initial phase of the injection procedure was considered as the quantifier for comparison because of its proportional relationship with the initial penetration depth during the injection process. Peak stagnation pressure indicates the maximum energy transformation that could happen between the microjet and skin tissues for an injection procedure. The results of this study indicated a tradeoff that exists between the attainable density and velocity of the microjet on the skin surface with variation in nozzle diameter; the optimum nozzle diameter was found to be within 200-250 µm under the present conditions. The authors also observed a discrepancy in the peak stagnation pressure value for lower filling ratios with variation in chamber diameter; hence, filling ratio of at least 50% was recommended for such systems. Furthermore, a 150% increase in the peak stagnation pressure was obtained with an angle of entry of 10°. In general, this study could provide valuable insights into the effect of geometrical parameters in the fluid dynamics characteristics of propelled microjets from the nozzle of a needle-free jet injector. Such information could be useful for the design of a mechanically driven needle-free jet injector having limited control over the energizing mechanism.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pele / Hidrodinâmica Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pele / Hidrodinâmica Idioma: En Ano de publicação: 2020 Tipo de documento: Article