Your browser doesn't support javascript.
loading
A field indoor air measurement of SARS-CoV-2 in the patient rooms of the largest hospital in Iran.
Faridi, Sasan; Niazi, Sadegh; Sadeghi, Kaveh; Naddafi, Kazem; Yavarian, Jila; Shamsipour, Mansour; Jandaghi, Nazanin Zahra Shafiei; Sadeghniiat, Khosro; Nabizadeh, Ramin; Yunesian, Masud; Momeniha, Fatemeh; Mokamel, Adel; Hassanvand, Mohammad Sadegh; MokhtariAzad, Talat.
Afiliação
  • Faridi S; Centre for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran; Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
  • Niazi S; International Laboratory for Air Quality and Health, School of Earth and Atmospheric Sciences, Science and Engineering Faculty, Queensland University of Technology (QUT), Brisbane, Queensland, Australia.
  • Sadeghi K; Department of Virology, School of Public Health, Tehran University of Medical Sciences.
  • Naddafi K; Centre for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran; Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
  • Yavarian J; Department of Virology, School of Public Health, Tehran University of Medical Sciences.
  • Shamsipour M; Department of Research Methodology and Data Analysis, Institute for Environmental Research, Tehran University of Medical Sciences, Tehran, Iran.
  • Jandaghi NZS; Department of Virology, School of Public Health, Tehran University of Medical Sciences.
  • Sadeghniiat K; Occupational Sleep Research Center, Baharloo Hospital, Tehran University of Medical Sciences, Tehran, Iran.
  • Nabizadeh R; Centre for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran; Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
  • Yunesian M; Centre for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran; Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
  • Momeniha F; Department of Environmental Health Engineering, School of Public Health, Iran University of Medical Sciences, Tehran, Iran.
  • Mokamel A; Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
  • Hassanvand MS; Centre for Air Pollution Research (CAPR), Institute for Environmental Research (IER), Tehran University of Medical Sciences, Tehran, Iran. Electronic address: Hassanvand@tums.ac.ir.
  • MokhtariAzad T; Department of Virology, School of Public Health, Tehran University of Medical Sciences. Electronic address: mokhtari@tums.ac.ir.
Sci Total Environ ; 725: 138401, 2020 Jul 10.
Article em En | MEDLINE | ID: mdl-32283308
ABSTRACT
The coronavirus disease 2019 (COVID-19) emerged in Wuhan city, China, in late 2019 and has rapidly spread throughout the world. The major route of transmission of SARS-CoV-2 is in contention, with the airborne route a likely transmission pathway for carrying the virus within indoor environments. Until now, there has been no evidence for detection of airborne severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and this may have implication for the potential spread of the COVID-19. We investigated the air of patient rooms with confirmed COVID-19 in the largest hospital in Iran, on March 17, 2020. To collect the SARS-CoV-2 particles, ten air samples were collected into the sterile standard midget impingers containing 20 mL DMEM with 100 µg/mL streptomycin, 100 U/mL penicillin and 1% antifoam reagent for 1 h. Besides, indoor particle number concentrations, CO2, relative humidity and temperature were recorded throughout the sampling duration. Viral RNA was extracted from samples taken from the impingers and Reverse-Transcription PCR (RT-PCR) was applied to confirm the positivity of collected samples based on the virus genome sequence. Fortunately, in this study all air samples which were collected 2 to 5 m from the patients' beds with confirmed COVID-19 were negative. Despite we indicated that all air samples were negative, however, we suggest further in vivo experiments should be conducted using actual patient cough, sneeze and breath aerosols in order to show the possibility of generation of the airborne size carrier aerosols and the viability fraction of the embedded virus in those carrier aerosols.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pneumonia Viral / Infecções por Coronavirus / Pandemias / Betacoronavirus Limite: Humans País/Região como assunto: Asia Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pneumonia Viral / Infecções por Coronavirus / Pandemias / Betacoronavirus Limite: Humans País/Região como assunto: Asia Idioma: En Ano de publicação: 2020 Tipo de documento: Article