Your browser doesn't support javascript.
loading
3D whole-heart isotropic sub-millimeter resolution coronary magnetic resonance angiography with non-rigid motion-compensated PROST.
Bustin, Aurélien; Rashid, Imran; Cruz, Gastao; Hajhosseiny, Reza; Correia, Teresa; Neji, Radhouene; Rajani, Ronak; Ismail, Tevfik F; Botnar, René M; Prieto, Claudia.
Afiliação
  • Bustin A; Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.
  • Rashid I; Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.
  • Cruz G; Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.
  • Hajhosseiny R; Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.
  • Correia T; National Heart and Lung Institute, Imperial College London, London, UK.
  • Neji R; Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.
  • Rajani R; Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.
  • Ismail TF; MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK.
  • Botnar RM; Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, 3rd Floor, Lambeth Wing, London, SE1 7EH, UK.
  • Prieto C; Department of Cardiology, Guy's & St Thomas' Hospitals, London, UK.
J Cardiovasc Magn Reson ; 22(1): 24, 2020 04 16.
Article em En | MEDLINE | ID: mdl-32299445
ABSTRACT

BACKGROUND:

To enable free-breathing whole-heart sub-millimeter resolution coronary magnetic resonance angiography (CMRA) in a clinically feasible scan time by combining low-rank patch-based undersampled reconstruction (3D-PROST) with a highly accelerated non-rigid motion correction framework.

METHODS:

Non-rigid motion corrected CMRA combined with 2D image-based navigators has been previously proposed to enable 100% respiratory scan efficiency in modestly undersampled acquisitions. Achieving sub-millimeter isotropic resolution with such techniques still requires prohibitively long acquisition times. We propose to combine 3D-PROST reconstruction with a highly accelerated non-rigid motion correction framework to achieve sub-millimeter resolution CMRA in less than 10 min. Ten healthy subjects and eight patients with suspected coronary artery disease underwent 4-5-fold accelerated free-breathing whole-heart CMRA with 0.9 mm3 isotropic resolution. Vessel sharpness, vessel length and image quality obtained with the proposed non-rigid (NR) PROST approach were compared against translational correction only (TC-PROST) and a previously proposed NR motion-compensated technique (non-rigid SENSE) in healthy subjects. For the patient study, image quality scoring and visual comparison with coronary computed tomography angiography (CCTA) were performed.

RESULTS:

Average scan times [mins] were 601 ± 059 (healthy subjects) and 829 ± 141 (patients). In healthy subjects, vessel sharpness of the left anterior descending (LAD) and right (RCA) coronary arteries were improved with the proposed non-rigid PROST (LAD 51.2 ± 8.8%, RCA 61.2 ± 9.1%) in comparison to TC-PROST (LAD 43.8 ± 5.1%, P = 0.051, RCA 54.3 ± 8.3%, P = 0.218) and non-rigid SENSE (LAD 46.1 ± 5.8%, P = 0.223, RCA 56.7 ± 9.6%, P = 0.50), although differences were not statistically significant. The average visual image quality score was significantly higher for NR-PROST (LAD 3.2 ± 0.6, RCA 3.3 ± 0.7) compared with TC-PROST (LAD 2.1 ± 0.6, P = 0.018, RCA 2.0 ± 0.7, P = 0.014) and non-rigid SENSE (LAD 2.3 ± 0.5, P = 0.008, RCA 2.5 ± 0.7, P = 0.016). In patients, the proposed approach showed good delineation of the coronaries, in agreement with CCTA, with image quality scores and vessel sharpness similar to that of healthy subjects.

CONCLUSIONS:

We demonstrate the feasibility of combining high undersampling factors with non-rigid motion-compensated reconstruction to obtain high-quality sub-millimeter isotropic CMRA images in ~ 8 min. Validation in a larger cohort of patients with coronary artery disease is now warranted.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Angiografia Coronária / Angiografia por Ressonância Magnética / Vasos Coronários / Imageamento Tridimensional Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Angiografia Coronária / Angiografia por Ressonância Magnética / Vasos Coronários / Imageamento Tridimensional Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article