In Vitro Characterization of a Novel Human Acellular Dermal Matrix (BellaCell HD) for Breast Reconstruction.
Nam, Sun-Young; Youn, Dayoung; Kim, Gyeong Hoe; Chai, Ji Hwa; Lim, Hyang Ran; Jung, Hong Hee; Heo, Chan Yeong.
Afiliação
  • Nam SY; Department of Plastic & Reconstructive Surgery, Seoul National University Bundang Hospital, Seongnam 13620, Korea.
  • Youn D; Department of Plastic & Reconstructive Surgery, Seoul National University Bundang Hospital, Seongnam 13620, Korea.
  • Kim GH; Department of Plastic and Reconstructive Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul 03080, Korea.
  • Chai JH; The Institute of Tissue Engineering, HansBiomed Co. LTD., Daejeon 34054, Korea.
  • Lim HR; The Institute of Tissue Engineering, HansBiomed Co. LTD., Daejeon 34054, Korea.
  • Jung HH; The Institute of Tissue Engineering, HansBiomed Co. LTD., Daejeon 34054, Korea.
  • Heo CY; Department of Plastic & Reconstructive Surgery, Seoul National University Bundang Hospital, Seongnam 13620, Korea.
Bioengineering (Basel) ; 7(2)2020 Apr 28.
Article em En | MEDLINE | ID: mdl-32353944
ABSTRACT
In the past, acellular dermal matrices (ADMs) have been used in implant-based breast reconstruction. Various factors affect the clinical performance of ADMs since there is a lack of systematic characterization of ADM tissues. This study used BellaCell HD and compared it to two commercially available ADMs-AlloDerm Ready to Use (RTU) and DermACELL-under in vitro settings. Every ADM was characterized to examine compatibility through cell cytotoxicity, proliferation, and physical features like tensile strength, stiffness, and the suture tensile strength. The BellaCell HD displayed complete decellularization in comparison with the other two ADMs. Several fibroblasts grew in the BellaCell HD with no cytotoxicity. The proliferation level of fibroblasts in the BellaCell HD was higher, compared to the AlloDerm RTU and DermACELL, after 7 and 14 days. The BellaCell HD had a load value of 444.94 N, 22.44 tensile strength, and 118.41% elongation ratio, and they were higher than in the other two ADMs. There was no significant discrepancy in the findings of stiffness evaluation and suture retention strength test. The study had some limitations because there were many other more factors useful in ADM's testing. In the study, BellaCell HD showed complete decellularization, high biocompatibility, low cytotoxicity, high tensile strength, high elongation, and high suture retention strengths. These characteristics make BellaCell HD a suitable tissue for adequate and safe use in implant-based breast reconstruction in humans.