Your browser doesn't support javascript.
loading
Variability of relationship between the volume scattering function at 180° and the backscattering coefficient for aquatic particles.
Appl Opt ; 59(10): C31-C41, 2020 Apr 01.
Article em En | MEDLINE | ID: mdl-32400563
Properly interpreting lidar (light detection and ranging) signal for characterizing particle distribution relies on a key parameter, χp(π), which relates the particulate volume scattering function (VSF) at 180° (ßp(π)) that a lidar measures to the particulate backscattering coefficient (bbp). However, χp(π) has been seldom studied due to challenges in accurately measuring ßp(π) and bbp concurrently in the field. In this study, χp(π), as well as its spectral dependence, was re-examined using the VSFs measured in situ at high angular resolution in a wide range of waters. ßp(π), while not measured directly, was inferred using a physically sound, well-validated VSF-inversion method. The effects of particle shape and internal structure on the inversion were tested using three inversion kernels consisting of phase functions computed for particles that are assumed as homogenous sphere, homogenous asymmetric hexahedra, or coated sphere. The reconstructed VSFs using any of the three kernels agreed well with the measured VSFs with a mean percentage difference <5% at scattering angles <170∘. At angles immediately near or equal to 180°, the reconstructed ßp(π) depends strongly on the inversion kernel. χp(π) derived with the sphere kernels was smaller than those derived with the hexahedra kernel but consistent with χp(π) estimated directly from high-spectral-resolution lidar and in situ backscattering sensor. The possible explanation was that the sphere kernels are able to capture the backscattering enhancement feature near 180° that has been observed for marine particles. χp(π) derived using the coated sphere kernel was generally lower than those derived with the homogenous sphere kernel. Our result suggests that χp(π) is sensitive to the shape and internal structure of particles and significant error could be induced if a fixed value of χp(π) is to be used to interpret lidar signal collected in different waters. On the other hand, χp(π) showed little spectral dependence.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article