Hypomagnesemia after heart transplantation or left ventricular assist device implant for end-stage heart failure.
Clin Transplant
; 34(8): e13902, 2020 08.
Article
em En
| MEDLINE
| ID: mdl-32406532
ABSTRACT
BACKGROUND:
Patients with advanced heart failure undergoing heart transplant (HTx) or left ventricular assist device (LVAD) implant are at high risk of magnesium deficiency, that may favor development of diabetes. We aimed to comparatively assess prevalence and correlates of hypomagnesemia during cardiac rehabilitation between 51 HTx and 46 LVAD recipients. METHODS ANDRESULTS:
We measured serum magnesium and correlated it to clinical and laboratory findings upon admission (T1 ) and at discharge (T2) from cardiac rehabilitation. Among LVAD, magnesium levels increased from admission to discharge. Among HTx, magnesium concentrations were below normal in 33% and 47% at T1 and T2 , respectively, and decreased from admission to discharge. HTx on tacrolimus showed greater decreases in magnesium and increases in glucose levels than those on cyclosporine. Magnesium levels were inversely associated with >15 mg/dL increased glucose concentrations between T2 and T1 (HR 0.373, 95% CI 0.154-0.903, P = .029) after adjustment for pre-existing diabetes, insulin resistance markers, calcineurin inhibitors (cyclosporine/tacrolimus), prednisone doses, and magnesium supplementation.CONCLUSION:
Hypomagnesemia is rare in LVAD recipients, but common within 1 month from HTx, worsens during rehabilitation, despite immunosuppression tapering and magnesium supplements, and is independently associated to increasing glucose levels. Studies evaluating whether correcting hypomagnesemia improves outcome are warranted.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Coração Auxiliar
/
Transplante de Coração
/
Insuficiência Cardíaca
Tipo de estudo:
Risk_factors_studies
Limite:
Humans
Idioma:
En
Ano de publicação:
2020
Tipo de documento:
Article