SARS-CoV-2 detection by direct rRT-PCR without RNA extraction.
J Clin Virol
; 128: 104423, 2020 07.
Article
em En
| MEDLINE
| ID: mdl-32416598
ABSTRACT
Rapid and reliable screening of SARS-CoV-2 is fundamental to assess viral spread and limit the pandemic we are facing. In this study, we compared direct rRT-PCR method (without RNA extraction) using SeeGene AllplexTM 2019-nCoV rRT-PCR with the RealStar® SARS-CoV-2 rRT-PCR kit (Altona Diagnostics). Furthermore, we assessed the impact of swab storage media composition on PCR efficiency. We show that SeeGene and Altona's assays provide similar efficiency. Importantly, we provide evidence that RNA extraction can be successfully bypassed when samples are stored in UTM medium or in molecular water but not when samples are stored in saline solution and in Hanks medium.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Pneumonia Viral
/
Manejo de Espécimes
/
Infecções por Coronavirus
/
Reação em Cadeia da Polimerase Via Transcriptase Reversa
/
Betacoronavirus
Limite:
Humans
Idioma:
En
Ano de publicação:
2020
Tipo de documento:
Article