[Validity and reliability of the Niño Jesús Hospital procedural sedation-analgesia scale of the under deep sedation-analgesia]. / Validez y fiabilidad de la escala de sedación para procedimientos del Hospital Niño Jesús bajo sedoanalgesia profunda.
Lozano-Díaz, David; Valdivielso Serna, Alberto; Garrido Palomo, Ramón; Arias-Arias, Ángel; Tárraga López, Pedro J; Martínez Gutiérrez, Andrés.
Afiliação
  • Lozano-Díaz D; Servicio de Pediatría, Hospital General La Mancha Centro, Alcázar de San Juan, Ciudad Real, España. Electronic address: david.lodi15@gmail.com.
  • Valdivielso Serna A; Unidad de Analgesia y Sedación, Hospital Universitario Niño Jesús, Madrid, España.
  • Garrido Palomo R; Servicio de Pediatría, Hospital General La Mancha Centro, Alcázar de San Juan, Ciudad Real, España.
  • Arias-Arias Á; Unidad de Investigación, Hospital General La Mancha Centro, Alcázar de San Juan, Ciudad Real, España.
  • Tárraga López PJ; Universidad de Castilla-La Mancha, Albacete, España.
  • Martínez Gutiérrez A; Servicio de Pediatría, Hospital General Universitario de Albacete, Albacete, España.
An Pediatr (Engl Ed) ; 94(1): 36-45, 2021 Jan.
Article em Es | MEDLINE | ID: mdl-32456877
ABSTRACT

INTRODUCTION:

The procedural sedation scale of the Niño Jesús Hospital (Madrid) (SSPNJH) has not been validated. PATIENTS AND

METHODS:

A prospective analytical study was conducted in 2 hospitals on patients ≥ 6 months undergoing invasive procedures using sedation-analgesia with propofol or midazolam and fentanyl. All were monitored using the bispectral index (BIS). Videos were made of each procedure, which were then edited and randomised. A total of 150 videos were rated by four observers using the SSPNJH, the sedation scale of the University of Michigan (UMSS), and the Ramsay Scale (SR). These observers were blinded to the BIS, and at the time of drug administration. To assess test-retest reliability, 50 of the initial 150 randomly selected videos were re-assessed.

RESULTS:

The study included a total of 65 patients. The within-observer agreement was high (ρ = 0.793). The SSPNJH gave a good interobserver reliability when compared with the UMSS (ICC = 0.88) and the SR (ICC = 0.86), and there was none with the BIS. Internal consistency was moderate (α = 0.68). Construct validity was demonstrated by changes in scores after administering sedatives (p < 0.0001). The SSPNJH had a very low correlation with the BIS (r = -0.166), and a moderate correlation with the UMSS (r = 0.497) and the SR (r = 0.405). As regards the applicability, this scale has been used in two hospitals in five different areas by four professionals of different categories.

CONCLUSIONS:

The SSPNJH is valid, reliable and applicable for sedation monitoring in invasive procedures under deep sedation-analgesia in paediatric patients. The SSPNJH has worse properties than the UMSS and the SR.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sedação Profunda / Analgesia / Monitorização Fisiológica Tipo de estudo: Clinical_trials / Observational_studies Limite: Child / Humans País/Região como assunto: Europa Idioma: Es Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sedação Profunda / Analgesia / Monitorização Fisiológica Tipo de estudo: Clinical_trials / Observational_studies Limite: Child / Humans País/Região como assunto: Europa Idioma: Es Ano de publicação: 2021 Tipo de documento: Article