Your browser doesn't support javascript.
loading
A Novel Aortic Regurgitation Model from Cusp Prolapse with Hemodynamic Validation Using an Ex Vivo Left Heart Simulator.
Zhu, Yuanjia; Imbrie-Moore, Annabel M; Paulsen, Michael J; Priromprintr, Bryant; Park, Matthew H; Wang, Hanjay; Lucian, Haley J; Farry, Justin M; Woo, Y Joseph.
Afiliação
  • Zhu Y; Department of Cardiothoracic Surgery, Stanford University, Stanford, CA, USA.
  • Imbrie-Moore AM; Department of Bioengineering, Stanford University, Stanford, CA, USA.
  • Paulsen MJ; Department of Cardiothoracic Surgery, Stanford University, Stanford, CA, USA.
  • Priromprintr B; Department of Mechanical Engineering, Stanford University, Stanford, CA, USA.
  • Park MH; Department of Cardiothoracic Surgery, Stanford University, Stanford, CA, USA.
  • Wang H; Department of Pediatrics, Division of Pediatric Cardiology, Lucile Packard Children's Hospital, Stanford University, Stanford, CA, USA.
  • Lucian HJ; Department of Cardiothoracic Surgery, Stanford University, Stanford, CA, USA.
  • Farry JM; Department of Mechanical Engineering, Stanford University, Stanford, CA, USA.
  • Woo YJ; Department of Cardiothoracic Surgery, Stanford University, Stanford, CA, USA.
J Cardiovasc Transl Res ; 14(2): 283-289, 2021 04.
Article em En | MEDLINE | ID: mdl-32495264
ABSTRACT
Although ex vivo simulation is a valuable tool for surgical optimization, a disease model that mimics human aortic regurgitation (AR) from cusp prolapse is needed to accurately examine valve biomechanics. To simulate AR, four porcine aortic valves were explanted, and the commissure between the two largest leaflets was detached and re-implanted 5 mm lower to induce cusp prolapse. Four additional valves were tested in their native state as controls. All valves were tested in a heart simulator while hemodynamics, high-speed videography, and echocardiography data were collected. Our AR model successfully reproduced cusp prolapse with significant increase in regurgitant volume compared with that of the controls (23.2 ± 8.9 versus 2.8 ± 1.6 ml, p = 0.017). Hemodynamics data confirmed the simulation of physiologic disease conditions. Echocardiography and color flow mapping demonstrated the presence of mild to moderate eccentric regurgitation in our AR model. This novel AR model has enormous potential in the evaluation of valve biomechanics and surgical repair techniques. Graphical Abstract.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Insuficiência da Valva Aórtica / Prolapso da Valva Aórtica / Hemodinâmica / Modelos Cardiovasculares Limite: Animals Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Insuficiência da Valva Aórtica / Prolapso da Valva Aórtica / Hemodinâmica / Modelos Cardiovasculares Limite: Animals Idioma: En Ano de publicação: 2021 Tipo de documento: Article