Your browser doesn't support javascript.
loading
A Symmetric Prior for the Regularisation of Elastic Deformations: Improved anatomical plausibility in nonlinear image registration.
Lange, Frederik J; Ashburner, John; Smith, Stephen M; Andersson, Jesper L R.
Afiliação
  • Lange FJ; Centre for Functional MRI of the Brain (FMRIB), Wellcome Centre for Integrative Neuroimaging, Nuffield Department of Clinical Neurosciences, University of Oxford, John Radcliffe Hospital, Headley Way, Oxford, OX3 9DU, UK. Electronic address: frederik.lange@dtc.ox.ac.uk.
  • Ashburner J; Wellcome Centre for Human Neuroimaging, UCL Institute of Neurology, University College London, 12 Queen Square, London, WC1N 3BG, UK. Electronic address: j.ashburner@ucl.ac.uk.
  • Smith SM; Centre for Functional MRI of the Brain (FMRIB), Wellcome Centre for Integrative Neuroimaging, Nuffield Department of Clinical Neurosciences, University of Oxford, John Radcliffe Hospital, Headley Way, Oxford, OX3 9DU, UK. Electronic address: steve@fmrib.ox.ac.uk.
  • Andersson JLR; Centre for Functional MRI of the Brain (FMRIB), Wellcome Centre for Integrative Neuroimaging, Nuffield Department of Clinical Neurosciences, University of Oxford, John Radcliffe Hospital, Headley Way, Oxford, OX3 9DU, UK. Electronic address: jesper.andersson@ndcn.ox.ac.uk.
Neuroimage ; 219: 116962, 2020 10 01.
Article em En | MEDLINE | ID: mdl-32497785
ABSTRACT
Nonlinear registration is critical to many aspects of Neuroimaging research. It facilitates averaging and comparisons across multiple subjects, as well as reporting of data in a common anatomical frame of reference. It is, however, a fundamentally ill-posed problem, with many possible solutions which minimise a given dissimilarity metric equally well. We present a regularisation method capable of selectively driving solutions towards those which would be considered anatomically plausible by penalising unlikely lineal, areal and volumetric deformations. This penalty is symmetric in the sense that geometric expansions and contractions are penalised equally, which encourages inverse-consistency. We demonstrate that this method is able to significantly reduce local volume changes and shape distortions compared to state-of-the-art elastic (FNIRT) and plastic (ANTs) registration frameworks. Crucially, this is achieved whilst simultaneously matching or exceeding the registration quality of these methods, as measured by overlap scores of labelled cortical regions. Extensive leveraging of GPU parallelisation has allowed us to solve this highly computationally intensive optimisation problem while maintaining reasonable run times of under half an hour.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Encéfalo / Neuroimagem Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Encéfalo / Neuroimagem Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article