Your browser doesn't support javascript.
loading
Flow cytometric evaluation of platelet-leukocyte conjugate stability over time: methodological implications of sample handling and processing.
Singh, Ayesha; Coulter, Amanda R; Trainor, Patrick J; Singam, Narayana Sarma V; Aladili, Bahjat N; Amraotkar, Alok R; Owolabi, Ugochukwu S; DeFilippis, Andrew P.
Afiliação
  • Singh A; Division of Cardiovascular Medicine, University of Louisville School of Medicine, Louisville, KY, USA. ayesha.singh@louisville.edu.
  • Coulter AR; University of Louisville, Delia Baxter Biomedical Research Building, 580 South Preston Street, Rm. 307, Louisville, KY, 40202, USA. ayesha.singh@louisville.edu.
  • Trainor PJ; Division of Cardiovascular Medicine, University of Louisville School of Medicine, Louisville, KY, USA.
  • Singam NSV; Division of Cardiovascular Medicine, University of Louisville School of Medicine, Louisville, KY, USA.
  • Aladili BN; Applied Statistics, New Mexico State University, Las Cruces, NM, USA.
  • Amraotkar AR; Division of Cardiovascular Medicine, University of Louisville School of Medicine, Louisville, KY, USA.
  • Owolabi US; Division of Cardiovascular Medicine, University of Louisville School of Medicine, Louisville, KY, USA.
  • DeFilippis AP; Division of Cardiovascular Medicine, University of Louisville School of Medicine, Louisville, KY, USA.
J Thromb Thrombolysis ; 51(1): 120-128, 2021 Jan.
Article em En | MEDLINE | ID: mdl-32557223
ABSTRACT
Platelet activation and subsequent aggregation is a vital component of atherothrombosis resulting in acute myocardial infarction. Therefore, quantifying platelet aggregation is a valuable measure for elucidating the pathogenesis of acute coronary syndromes (ACS). Circulating platelet-monocyte conjugates (PMC) as determined by flow cytometry (FCM) are an important measure of in vivo platelet aggregation. However, the influence of sample handling on FCM measurement of PMC is not well-studied. The changes in FCM measurement of PMC with variation in sample handling techniques were evaluated. The stability of PMC concentrations over time with changes in fixation and immunolabeling intervals was assessed. The effect of Time-to-Fix and Time-to-Stain on FCM PMC measurements was investigated in five healthy volunteers. Time-to-Fix (i.e., interval between phlebotomy and sample fixation) was performed at 3, 30, and 60 min. Time-to-Stain (i.e., time of fixed sample storage to staining) was performed at 1, 24, and 48 h. Increasing Time-to-Stain from 1 to 24 or 48 h resulted in lower PMC measures (p < 0.0001). A statistically significant difference in PMC measurement with increasing Time-to-Fix was not observed (p < 0.41). Postponement of sample staining has deleterious effects on the measurement of PMC via FCM. Delays in immunolabeling of fixed samples compromised measurement of PMC by 30% over the first 24 h. Staining/FCM should be completed within an hour of collection.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Plaquetas / Monócitos / Agregação Plaquetária / Citometria de Fluxo Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Plaquetas / Monócitos / Agregação Plaquetária / Citometria de Fluxo Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article