Your browser doesn't support javascript.
loading
4D MRI: Robust sorting of free breathing MRI slices for use in interventional settings.
Gulamhussene, Gino; Joeres, Fabian; Rak, Marko; Pech, Maciej; Hansen, Christian.
Afiliação
  • Gulamhussene G; Faculty of Computer Science, Otto-von-Guericke University Magdeburg, Magdeburg, Germany.
  • Joeres F; Faculty of Computer Science, Otto-von-Guericke University Magdeburg, Magdeburg, Germany.
  • Rak M; Faculty of Computer Science, Otto-von-Guericke University Magdeburg, Magdeburg, Germany.
  • Pech M; Clinic for Radiology and Nuclear Medicine, University Hospital Magdeburg, Magdeburg, Germany.
  • Hansen C; Faculty of Computer Science, Otto-von-Guericke University Magdeburg, Magdeburg, Germany.
PLoS One ; 15(6): e0235175, 2020.
Article em En | MEDLINE | ID: mdl-32569335
ABSTRACT

PURPOSE:

We aim to develop a robust 4D MRI method for large FOVs enabling the extraction of irregular respiratory motion that is readily usable with all MRI machines and thus applicable to support a wide range of interventional settings.

METHOD:

We propose a 4D MRI reconstruction method to capture an arbitrary number of breathing states. It uses template updates in navigator slices and search regions for fast and robust vessel cross-section tracking. It captures FOVs of 255 mm x 320 mm x 228 mm at a spatial resolution of 1.82 mm x 1.82 mm x 4mm and temporal resolution of 200ms. A total of 37 4D MRIs of 13 healthy subjects were reconstructed to validate the method. A quantitative evaluation of the reconstruction rate and speed of both the new and baseline method was performed. Additionally, a study with ten radiologists was conducted to assess the subjective reconstruction quality of both methods.

RESULTS:

Our results indicate improved mean reconstruction rates compared to the baseline method (79.4% vs. 45.5%) and improved mean reconstruction times (24s vs. 73s) per subject. Interventional radiologists perceive the reconstruction quality of our method as higher compared to the baseline (262.5 points vs. 217.5 points, p = 0.02).

CONCLUSIONS:

Template updates are an effective and efficient way to increase 4D MRI reconstruction rates and to achieve better reconstruction quality. Search regions reduce reconstruction time. These improvements increase the applicability of 4D MRI as a base for seamless support of interventional image guidance in percutaneous interventions.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração / Imageamento por Ressonância Magnética Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração / Imageamento por Ressonância Magnética Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article