Your browser doesn't support javascript.
loading
Atomic Force Microscopy Imaging in Turbid Liquids: A Promising Tool in Nanomedicine.
Leitner, Michael; Seferovic, Hannah; Stainer, Sarah; Buchroithner, Boris; Schwalb, Christian H; Deutschinger, Alexander; Ebner, Andreas.
Afiliação
  • Leitner M; Institute of Biophysics, Johannes Kepler University, Gruberstraße 40, 4020 Linz, Austria.
  • Seferovic H; Institute of Biophysics, Johannes Kepler University, Gruberstraße 40, 4020 Linz, Austria.
  • Stainer S; Institute of Biophysics, Johannes Kepler University, Gruberstraße 40, 4020 Linz, Austria.
  • Buchroithner B; Institute of Biophysics, Johannes Kepler University, Gruberstraße 40, 4020 Linz, Austria.
  • Schwalb CH; GETec Microscopy GmbH, Seestadtstraße 27/Top 27, 1220 Vienna, Austria.
  • Deutschinger A; SCL-Sensor.Tech. Fabrication GmbH, Seestadtstraße 27/Top 27, 1220 Vienna, Austria.
  • Ebner A; Institute of Biophysics, Johannes Kepler University, Gruberstraße 40, 4020 Linz, Austria.
Sensors (Basel) ; 20(13)2020 Jul 02.
Article em En | MEDLINE | ID: mdl-32630829
ABSTRACT
Tracking of biological and physiological processes on the nanoscale is a central part of the growing field of nanomedicine. Although atomic force microscopy (AFM) is one of the most appropriate techniques in this area, investigations in non-transparent fluids such as human blood are not possible with conventional AFMs due to limitations caused by the optical readout. Here, we show a promising approach based on self-sensing cantilevers (SSC) as a replacement for optical readout in biological AFM imaging. Piezo-resistors, in the form of a Wheatstone bridge, are embedded into the cantilever, whereas two of them are placed at the bending edge. This enables the deflection of the cantilever to be precisely recorded by measuring the changes in resistance. Furthermore, the conventional acoustic or magnetic vibration excitation in intermittent contact mode can be replaced by a thermal excitation using a heating loop. We show further developments of existing approaches enabling stable measurements in turbid liquids. Different readout and excitation methods are compared under various environmental conditions, ranging from dry state to human blood. To demonstrate the applicability of our laser-free bio-AFM for nanomedical research, we have selected the hemostatic process of blood coagulation as well as ultra-flat red blood cells in different turbid fluids. Furthermore, the effects on noise and scanning speed of different media are compared. The technical realization is shown (1) on a conventional optical beam deflection (OBD)-based AFM, where we replaced the optical part by a new SSC nose cone, and (2) on an all-electric AFM, which we adapted for measurements in turbid liquids.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acústica / Microscopia de Força Atômica / Nanomedicina Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acústica / Microscopia de Força Atômica / Nanomedicina Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article