Vertical Shear Pelvic Ring Injury Adjacent to Retained Pelvic Hardware: A Case Report.
Yee, Michael A; Miles, Daniel T; Nowotarski, Peter J.
Afiliação
  • Yee MA; Department of Orthopaedic Surgery, University of Tennessee at Chattanooga, Chattanooga, Tennessee.
JBJS Case Connect ; 10(2): e0601, 2020.
Article em En | MEDLINE | ID: mdl-32649127
CASE: A 47-year-old obese woman presented with a vertical shear (VS) pelvic ring injury after a motor vehicle accident around her previous posterior pelvic hardware. The patient underwent closed reduction with percutaneous posterior screw fixation using combined fluoroscopy and O-arm (Medtronic). CONCLUSION: A rare case of VS pelvic injury with indwelling posterior pelvic hardware does not automatically preclude placement of percutaneous sacroiliac and transiliac-transsacral screws. Combining fluoroscopic imaging and O-arm enables safe screw placement, saving patients from invasive surgeries.