Your browser doesn't support javascript.
loading
Do 3-D Printed Handheld Models Improve Surgeon Reliability for Recognition of Intraarticular Distal Radius Fracture Characteristics?
Langerhuizen, David W G; Doornberg, Job N; Janssen, Michiel M A; Kerkhoffs, Gino M M J; Jaarsma, Ruurd L; Janssen, Stein J.
Afiliação
  • Langerhuizen DWG; D. W. G. Langerhuizen, G. M. M. J. Kerkhoffs, S. J. Janssen, Department of Orthopaedic Surgery, Amsterdam Movement Sciences, Amsterdam University Medical Centre, Amsterdam, the Netherlands.
  • Doornberg JN; J. N. Doornberg, M. M. A Janssen, R. L. Jaarsma, Department of Orthopaedic & Trauma Surgery, Flinders University, Flinders Medical Centre, Adelaide, Australia.
  • Janssen MMA; J. N. Doornberg, M. M. A Janssen, R. L. Jaarsma, Department of Orthopaedic & Trauma Surgery, Flinders University, Flinders Medical Centre, Adelaide, Australia.
  • Kerkhoffs GMMJ; D. W. G. Langerhuizen, G. M. M. J. Kerkhoffs, S. J. Janssen, Department of Orthopaedic Surgery, Amsterdam Movement Sciences, Amsterdam University Medical Centre, Amsterdam, the Netherlands.
  • Jaarsma RL; J. N. Doornberg, M. M. A Janssen, R. L. Jaarsma, Department of Orthopaedic & Trauma Surgery, Flinders University, Flinders Medical Centre, Adelaide, Australia.
  • Janssen SJ; D. W. G. Langerhuizen, G. M. M. J. Kerkhoffs, S. J. Janssen, Department of Orthopaedic Surgery, Amsterdam Movement Sciences, Amsterdam University Medical Centre, Amsterdam, the Netherlands.
Clin Orthop Relat Res ; 478(12): 2901-2908, 2020 12.
Article em En | MEDLINE | ID: mdl-32667759
ABSTRACT

BACKGROUND:

For fracture care, radiographs and two-dimensional (2-D) and three-dimensional (3-D) CT are primarily used for preoperative planning and postoperative evaluation. Intraarticular distal radius fractures are technically challenging to treat, and meticulous preoperative planning is paramount to improve the patient's outcome. Three-dimensionally printed handheld models might improve the surgeon's interpretation of specific fracture characteristics and patterns preoperatively and could therefore be clinically valuable; however, the additional value of 3-D printed handheld models for fractures of the distal radius, a high-volume and commonly complex fracture due to its intraarticular configuration, has yet to be determined. QUESTIONS/

PURPOSES:

(1) Does the reliability of assessing specific fracture characteristics that guide surgical decision-making for distal radius fractures improve with 3-D printed handheld models? (2) Does surgeon agreement on the overall fracture classification improve with 3-D printed handheld models? (3) Does the surgeon's confidence improve when assessing the overall fracture configuration with an additional 3-D model?

METHODS:

We consecutively included 20 intraarticular distal radius fractures treated at a Level 1 trauma center between May 2018 and November 2018. Ten surgeons evaluated the presence or absence of specific fracture characteristics (volar rim fracture, die punch, volar lunate facet, dorsal comminution, step-off > 2 mm, and gap > 2 mm), fracture classification according to the AO/Orthopaedic Trauma Association (OTA) classification scheme, and their confidence in assessing the overall fracture according to the classification scheme, rated on a scale from 0 to 10 (0 = not at all confident to 10 = very confident). Of 10 participants regularly treating distal radius fractures, seven were orthopaedic trauma surgeons and three upper limb surgeons with experience levels ranging from 1 to 25 years after completion of residency training. Fractures were assessed twice, with 1 month between each assessment. Initially, fractures were assessed using radiographs and 2-D and 3-D CT images (conventional assessment); the second time, the evaluation was based on radiographs and 2-D and 3-D CT images with an additional 3-D handheld model (3-D printed handheld model assessment). On both occasions, fracture characteristics were evaluated upon a surgeon's own interpretation, without specific instruction before assessment. We provided a sheet demonstrating the AO/OTA classification scheme before evaluation on each session. Multi-rater Fleiss's kappa was used to determine intersurgeon reliability for assessing fracture characteristics and classification. Confidence regarding assessment of the overall fracture classification was assessed using a paired t-test.

RESULTS:

We found that 3-D printed models of intraarticular distal radius fractures led to no change in kappa values for the reliability of all characteristics volar rim (conventional kappa 0.19 [95% CI 0.06 to 0.32], kappa for 3-D handheld model 0.23 [95% CI 0.11 to 0.36], difference of kappas 0.04 [95% CI -0.14 to 0.22]; p = 0.66), die punch (conventional kappa 0.38 [95% CI 0.15 to 0.61], kappa for 3-D handheld model 0.50 [95% CI 0.23 to 0.78], difference of kappas 0.12 [95% CI -0.23 to 0.47]; p = 0.52), volar lunate facet (conventional kappa 0.31 [95% CI 0.14 to 0.49], kappa for 3-D handheld model 0.48 [95% CI 0.23 to 0.72], difference of kappas 0.17 [95% CI -0.12 to 0.46]; p = 0.26), dorsal comminution (conventional kappa 0.36 [95% CI 0.13 to 0.58], kappa for 3-D handheld model 0.31 [95% CI 0.11 to 0.51], difference of kappas -0.05 [95% CI -0.34 to 0.24]; p = 0.74), step-off > 2 mm (conventional kappa 0.55 [95% CI 0.29 to 0.82], kappa for 3-D handheld model 0.58 [95% CI 0.31 to 0.85], difference of kappas 0.03 [95% CI -0.34 to 0.40]; p = 0.87), gap > 2 mm (conventional kappa 0.59 [95% CI 0.39 to 0.79], kappa for 3-D handheld model 0.69 [95% CI 0.50 to 0.89], difference of kappas 0.10 [95% CI -0.17 to 0.37]; p = 0.48). Although there appeared to be categorical improvement in kappa values for some fracture characteristics, overlapping CIs indicated no change. Fracture classification did not improve (conventional diagnostics kappa 0.27 [95% CI 0.14 to 0.39], conventional diagnostics with an additional 3-D handheld model kappa 0.25 [95% CI 0.15 to 0.35], difference of kappas -0.02 [95% CI -0.18 to 0.14]; p = 0.81). There was no improvement in self-assessed confidence in terms of assessment of overall fracture configuration when a 3-D model was added to the evaluation process (conventional diagnostics 7.8 [SD 0.79 {95% CI 7.2 to 8.3}], 3-D handheld model 8.5 [SD 0.71 {95% CI 8.0 to 9.0}], difference of score 0.7 [95% CI -1.69 to 0.16], p = 0.09).

CONCLUSIONS:

Intersurgeon reliability for evaluating the characteristics of and classifying intraarticular distal radius fractures did not improve with an additional 3-D model. Further studies should evaluate the added value of 3-D printed handheld models for teaching surgical residents and medical trainees to define the future role of 3-D printing in caring for fractures of the distal radius. LEVEL OF EVIDENCE Level II, diagnostic study.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Rádio (Anatomia) / Fraturas do Rádio / Tomografia Computadorizada por Raios X / Modelagem Computacional Específica para o Paciente / Impressão Tridimensional / Modelos Anatômicos Tipo de estudo: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Rádio (Anatomia) / Fraturas do Rádio / Tomografia Computadorizada por Raios X / Modelagem Computacional Específica para o Paciente / Impressão Tridimensional / Modelos Anatômicos Tipo de estudo: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article