Your browser doesn't support javascript.
loading
[Dose Verification for Respiratory-gated VMAT-SBRT Using Real-time Tumor Tracking System].
Kawamura, Tetsuro; Fujii, Yusuke; Tokura, Shinsuke; Kaneda, Kazunori; Fujita, Masahiro; Murakami, Naoki; Kuriyama, Yukiharu; Miyawaki, Daisuke; Hase, Mamoru.
Afiliação
  • Kawamura T; Department of Radiological Technology, Kakogawa Central City Hospital.
  • Fujii Y; Department of Radiological Technology, Kakogawa Central City Hospital.
  • Tokura S; Department of Radiological Technology, Kakogawa Central City Hospital.
  • Kaneda K; Department of Radiological Technology, Kakogawa Central City Hospital.
  • Fujita M; Department of Radiological Technology, Kakogawa Central City Hospital.
  • Murakami N; Department of Radiological Technology, Kakogawa Central City Hospital.
  • Kuriyama Y; Department of Radiological Technology, Kakogawa Central City Hospital.
  • Miyawaki D; Division of Radiation Oncology, Kobe University Graduate School of Medicine.
  • Hase M; Department of Radiology, Kakogawa Central City Hospital.
Article em Ja | MEDLINE | ID: mdl-32684560
ABSTRACT
Recently, the introduction of various novel technologies in clinical settings has improved the accuracy of radiation therapy. Stereotactic body radiation therapy (SBRT) involves the delivery of an accurate radiation dose to the tumor with a minimal impact on normal tissues using various measures to address changes in the tumor position due to respiratory displacement. The SyncTraX FX4 real-time tumor tracking system (Shimadzu Corporation) introduced in our hospital tracks the actual tumor location by radioscopically monitoring a metallic marker that is placed in the vicinity of the tumor. However, there have been no reports yet on respiratory-gated volumetric modulated arc therapy (VMAT)-SBRT using a real-time tumor tracking system. This study aimed to develop an irradiation procedure for respiratory-gated VMAT-SBRT using a real-time tumor tracking system and to evaluate radiation doses therein. In this study, we found that absolute doses with respiratory gating did not deviate by more than ±1.0% from those without respiratory gating. In addition, the pass rate in gamma analysis using GAFCHROMIC EBT3 was ³95% with the pass criteria in dose difference, distance to agreement, and threshold being 2%, 2 mm, and 10%, respectively. Furthermore, a trajectory log file analysis did not reveal any significant error causes. Thus, these data indicate that respiratory-gated VMAT-SBRT can be applied clinically.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiocirurgia / Radioterapia de Intensidade Modulada / Neoplasias Limite: Humans Idioma: Ja Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiocirurgia / Radioterapia de Intensidade Modulada / Neoplasias Limite: Humans Idioma: Ja Ano de publicação: 2020 Tipo de documento: Article