Your browser doesn't support javascript.
loading
Aortic root destruction after aortic valvuloplasty for bicuspid aortic valve.
Nakao, Mitsutaka; Yoshitake, Michio; Matsumura, Yoko; Takagi, Tomomitsu; Arimura, Satoshi; Nagahori, Ryuichi; Bando, Ko; Masuzawa, Akihiro; Ono, Minoru; Kunihara, Takashi.
Afiliação
  • Nakao M; Department of Cardiac Surgery, The Jikei University School of Medicine, 3-9-18, Nishi-shinbashi, Minato-ku, Tokyo, 105-8571, Japan. mit.nakao@jikei.ac.jp.
  • Yoshitake M; Department of Cardiac Surgery, The Jikei University School of Medicine, 3-9-18, Nishi-shinbashi, Minato-ku, Tokyo, 105-8571, Japan.
  • Matsumura Y; Department of Cardiac Surgery, The Jikei University School of Medicine, 3-9-18, Nishi-shinbashi, Minato-ku, Tokyo, 105-8571, Japan.
  • Takagi T; Department of Cardiac Surgery, The Jikei University School of Medicine, 3-9-18, Nishi-shinbashi, Minato-ku, Tokyo, 105-8571, Japan.
  • Arimura S; Department of Cardiac Surgery, The Jikei University School of Medicine, 3-9-18, Nishi-shinbashi, Minato-ku, Tokyo, 105-8571, Japan.
  • Nagahori R; Department of Cardiac Surgery, The Jikei University School of Medicine, 3-9-18, Nishi-shinbashi, Minato-ku, Tokyo, 105-8571, Japan.
  • Bando K; Department of Cardiac Surgery, The Jikei University School of Medicine, 3-9-18, Nishi-shinbashi, Minato-ku, Tokyo, 105-8571, Japan.
  • Masuzawa A; Department of Cardiac Surgery, The Jikei University School of Medicine, 3-9-18, Nishi-shinbashi, Minato-ku, Tokyo, 105-8571, Japan.
  • Ono M; Department of Cardiac Surgery, The University of Tokyo, Tokyo, Japan.
  • Kunihara T; Department of Cardiac Surgery, The Jikei University School of Medicine, 3-9-18, Nishi-shinbashi, Minato-ku, Tokyo, 105-8571, Japan.
Gen Thorac Cardiovasc Surg ; 69(2): 350-352, 2021 Feb.
Article em En | MEDLINE | ID: mdl-32712754
ABSTRACT
Ultrasound cardiography showed severe aortic regurgitation (AR) due to bicuspid aortic valve with dilatation of the aortic annulus and sinotubular junction in a 27-year-old man hospitalized with loss of consciousness. He underwent aortic valvuloplasty combined with external suture annuloplasty using an expanded polytetrafluoroethylene (ePTFE) suture. Intraoperative findings revealed thickening and adhesion of the aortic root despite the first surgery. He developed recurrent AR 7 months later and underwent redo surgery. An ePTFE suture was found inside the aorta. Aortic root replacement with a mechanical composite graft was performed, as reconstruction appeared difficult because the aortic annulus was damaged and there were multiple holes on all cusps. Here, we report a rare case of aortic root destruction after external suture annuloplasty.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Insuficiência da Valva Aórtica / Anuloplastia da Valva Cardíaca / Doença da Válvula Aórtica Bicúspide Tipo de estudo: Etiology_studies Limite: Adult / Humans / Male Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Insuficiência da Valva Aórtica / Anuloplastia da Valva Cardíaca / Doença da Válvula Aórtica Bicúspide Tipo de estudo: Etiology_studies Limite: Adult / Humans / Male Idioma: En Ano de publicação: 2021 Tipo de documento: Article