Your browser doesn't support javascript.
loading
The value of saline-aided ultrasound in diagnosing congenital duodenal obstruction.
Yang, Boyang; Huang, Danping; Zhou, Luyao; Zhong, Wei; He, Qiuming; Wang, Zhe; Fang, Qian; Wang, Hongying.
Afiliação
  • Yang B; Department of Medical Ultrasonics, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, No. 9 of Jin Sui Road, Guangzhou, 510623, China.
  • Huang D; Department of Medical Ultrasonics, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, No. 9 of Jin Sui Road, Guangzhou, 510623, China.
  • Zhou L; Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, 510080, China.
  • Zhong W; Department of Neonatal Surgery and Neonatal Surgical Intensive Care Unit, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, Guangzhou, 510623, China.
  • He Q; Department of Neonatal Surgery and Neonatal Surgical Intensive Care Unit, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, Guangzhou, 510623, China.
  • Wang Z; Department of Neonatal Surgery and Neonatal Surgical Intensive Care Unit, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, Guangzhou, 510623, China.
  • Fang Q; Department of Medical Ultrasonics, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, No. 9 of Jin Sui Road, Guangzhou, 510623, China.
  • Wang H; Department of Medical Ultrasonics, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, No. 9 of Jin Sui Road, Guangzhou, 510623, China. gzfe1122@163.com.
Pediatr Surg Int ; 36(10): 1197-1203, 2020 Oct.
Article em En | MEDLINE | ID: mdl-32715324
PURPOSE: The aim of the study is to assess the value of saline-aided ultrasound (US) in diagnosing congenital duodenal obstruction (CDO). METHODS: The neonates with CDO were enrolled in this study, including the neonates confirmed with annular pancreas (AP) by operation, the neonates confirmed with duodenal atresia, the neonates confirmed with duodenum web, and the neonates confirmed with malrotation. Pertinent data were recorded, including the US features, intraoperative findings, and surgical procedures. The methodology of this study is a diagnostic test study which means the US feature is the test and the intraoperative finding is the gold standard. RESULTS: A total of 95 neonates were enrolled, including 33 neonates with AP, 6 neonates with duodenal atresia, 29 neonates with duodenum web, and 27 neonates with malrotation. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the hyperechogenic band for the detection of AP were 78.8% (26/33), 90.3% (56/62), 81.2% (26/32), 88.8% (56/63), and 86.3% (82/95), respectively. The sensitivity, specificity, NPV, and accuracy for the detection of duodenal atresia were 0% (0/6), 100% (89/89), 93.6% (89/95), and 93.6% (89/95), respectively. The sensitivity, specificity, PPV, NPV, and accuracy for the detection of duodenum web were 100% (29/29), 100% (66/66), 100% (29/29), 100% (66/66), and 100% (95/95), respectively. The sensitivity, specificity, PPV, NPV, and accuracy for the detection of malrotation were 100% (27/27), 100% (68/68), 100% (27/27), 100% (68/68), and 100% (95/95), respectively. CONCLUSION: Saline-aided US is a feasible tool to diagnose CDO.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ultrassonografia / Obstrução Duodenal Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male / Newborn Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ultrassonografia / Obstrução Duodenal Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male / Newborn Idioma: En Ano de publicação: 2020 Tipo de documento: Article