Your browser doesn't support javascript.
loading
Novel loss of function mutation in NOTCH1 in a family with bicuspid aortic valve, ventricular septal defect, thoracic aortic aneurysm, and aortic valve stenosis.
Debiec, Radoslaw; Hamby, Stephen E; Jones, Peter D; Coolman, Sue; Asiani, Manish; Kharodia, Shireen; Skinner, Gregory J; Samani, Nilesh J; Webb, Tom R; Bolger, Aidan.
Afiliação
  • Debiec R; Department of Cardiovascular Sciences, University of Leicester, NIHR (National Institute for Health Research) Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK.
  • Hamby SE; Department of Cardiovascular Sciences, University of Leicester, NIHR (National Institute for Health Research) Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK.
  • Jones PD; Department of Cardiovascular Sciences, University of Leicester, NIHR (National Institute for Health Research) Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK.
  • Coolman S; Department of Cardiovascular Sciences, University of Leicester, NIHR (National Institute for Health Research) Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK.
  • Asiani M; Department of Cardiovascular Sciences, University of Leicester, NIHR (National Institute for Health Research) Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK.
  • Kharodia S; Department of Cardiovascular Sciences, University of Leicester, NIHR (National Institute for Health Research) Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK.
  • Skinner GJ; East Midlands Congenital Heart Centre, Glenfield Hospital, Leicester, UK.
  • Samani NJ; Department of Cardiovascular Sciences, University of Leicester, NIHR (National Institute for Health Research) Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK.
  • Webb TR; Department of Cardiovascular Sciences, University of Leicester, NIHR (National Institute for Health Research) Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK.
  • Bolger A; Department of Cardiovascular Sciences, University of Leicester, NIHR (National Institute for Health Research) Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK.
Mol Genet Genomic Med ; 8(10): e1437, 2020 10.
Article em En | MEDLINE | ID: mdl-32720365
ABSTRACT

BACKGROUND:

Bicuspid aortic valve is the most common congenital valvular heart defect in the general population. BAV is associated with significant morbidity due to valve failure, formation of thoracic aortic aneurysm, and increased risk of infective endocarditis and aortic dissection. Loss of function mutations in NOTCH1 (OMIM 190198) has previously been associated with congenital heart disease involving the aortic valve, left ventricle outflow tract, and mitral valve that segregates in affected pedigrees as an autosomal dominant trait with variable expressivity.

METHODS:

We performed whole-exome sequencing in four members of a three-generational family (three affected and one unaffected subject) with clinical phenotypes including aortic valve stenosis, thoracic aortic aneurysm, and ventricular septal defect.

RESULTS:

We identified 16 potentially damaging genetic variants (one stop variant, one splice variant, and 14 missense variants) cosegregating with the phenotype. Of these variants, the nonsense mutation (p.Tyr291*) in NOTCH1 was the most deleterious variant identified and the most likely variant causing the disease.

CONCLUSION:

Inactivating NOTCH1 mutations are a rare cause of familial heart disease involving predominantly left ventricular outflow tract lesions and characterized by the heterogeneity of clinical phenotype.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Aneurisma da Aorta Torácica / Receptor Notch1 / Mutação com Perda de Função / Doença da Válvula Aórtica Bicúspide / Comunicação Interventricular Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Aneurisma da Aorta Torácica / Receptor Notch1 / Mutação com Perda de Função / Doença da Válvula Aórtica Bicúspide / Comunicação Interventricular Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article