Your browser doesn't support javascript.
loading
Spectrally Resolved Fundus Autofluorescence in Healthy Eyes: Repeatability and Topographical Analysis of the Green-Emitting Fluorophores.
Borrelli, Enrico; Battista, Marco; Zuccaro, Biancamaria; Sacconi, Riccardo; Brambati, Maria; Querques, Lea; Prascina, Francesco; Sadda, SriniVas R; Bandello, Francesco; Querques, Giuseppe.
Afiliação
  • Borrelli E; Department of Ophthalmology, University Vita-Salute, IRCCS Ospedale San Raffaele, 20132 Milan, Italy.
  • Battista M; Department of Ophthalmology, University Vita-Salute, IRCCS Ospedale San Raffaele, 20132 Milan, Italy.
  • Zuccaro B; Department of Ophthalmology, University Vita-Salute, IRCCS Ospedale San Raffaele, 20132 Milan, Italy.
  • Sacconi R; Department of Ophthalmology, University Vita-Salute, IRCCS Ospedale San Raffaele, 20132 Milan, Italy.
  • Brambati M; Department of Ophthalmology, University Vita-Salute, IRCCS Ospedale San Raffaele, 20132 Milan, Italy.
  • Querques L; Department of Ophthalmology, University Vita-Salute, IRCCS Ospedale San Raffaele, 20132 Milan, Italy.
  • Prascina F; Department of Ophthalmology, University Vita-Salute, IRCCS Ospedale San Raffaele, 20132 Milan, Italy.
  • Sadda SR; Doheny Image Reading Center, Doheny Eye Institute, Los Angeles, CA 90033, USA.
  • Bandello F; Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, CA 90095, USA.
  • Querques G; Department of Ophthalmology, University Vita-Salute, IRCCS Ospedale San Raffaele, 20132 Milan, Italy.
J Clin Med ; 9(8)2020 Jul 27.
Article em En | MEDLINE | ID: mdl-32726903
ABSTRACT
The aim of this study was to report normal measurements of green-emitting fluorophores in the macula of healthy young individuals and to assess the repeatability of these quantitative metrics. To do so, healthy young volunteers were imaged twice (7 ± 3 days apart) using a confocal blue-light fundus autofluorescence (FAF) device with a shorter excitation wavelength (peak at 450 nm) and the capability for separately detecting the red and green components of the emission spectrum. The main outcome measure was the percentage of area occupied by green-emitting fluorophores in the macula. In addition, this measure was performed in separate regions providing a topographical assessment in the foveal, parafoveal and perifoveal regions. Furthermore, the level of agreement between repeated measurements was evaluated. Thirty eyes from 30 healthy volunteers were included in this analysis. Mean age was 26.2 ± 2.8 years (median 25.0 years; range 23.0-32.0 years). Median (interquartile range-IQR) area occupied by green-emitting fluorophores was 3.6% (1.9-4.7%) in the macular region. In the topographical analysis, this percentage was higher in the foveal area (median = 33.3%, IQR = 21.9-41.2%), as compared with both the parafoveal (median = 5.3%; IQR = 2.4-8.1%; p < 0.0001) and perifoveal (median = 0.5%, IQR = 0.2-0.8%; p < 0.0001) regions. The coefficient of variation (CV; ranging from 1.1% to 1.7% in the analyzed regions) and the intraclass correlation coefficient (ICC; ranging from 0.93 to 0.97) indicated high levels of repeatability. In conclusion, the assessment of green-emitting fluorophores is repeatable. The distribution of these fluorophores is highest in the foveal region. Assuming that flavin adenine dinucleotide (FAD) emits in the green autofluorescence spectrum, this variability could be secondary to an increased quantity of mitochondria in the foveal region.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article