Your browser doesn't support javascript.
loading
Low fouling strategy of electrochemical biosensor based on chondroitin sulfate functionalized gold magnetic particle for voltammetric determination of mycoplasma ovipneumonia in whole serum.
Zhao, Shiyi; Zhou, Yingxia; Wei, Lai; Chen, Lihua.
Afiliação
  • Zhao S; Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong, Key Laboratory of Eco-chemical Engineering, College of Chemistry and Molecular Eng
  • Zhou Y; Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong, Key Laboratory of Eco-chemical Engineering, College of Chemistry and Molecular Eng
  • Wei L; Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong, Key Laboratory of Eco-chemical Engineering, College of Chemistry and Molecular Eng
  • Chen L; Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong, Key Laboratory of Eco-chemical Engineering, College of Chemistry and Molecular Eng
Anal Chim Acta ; 1126: 91-99, 2020 Aug 22.
Article em En | MEDLINE | ID: mdl-32736729
ABSTRACT
Based on the successful design and preparation of Fe3O4@Au@polyethylene glycol (PEG)@chondroitin sulfate (CS) nanoparticles, a novel electrochemical biosensor was elaborately developed for MO determination by the drop coating method. This biosensor demonstrates ultra-low fouling properties in complex biological systems, especially in whole serum. Only 2.40% of the differential pulse voltammetry (DPV) signal changes are shown in the resistance test of electrode interface to 100% goat serum. The constructed biosensor also presented a good selectivity (DNA samples for M1, M2 and M3give a response around 14.2-21.4%of that obtained by the target analyte), reproducibility (the relative standard deviation (RSD) is only 4.82%) and storage stability (93.2% of the initial response is maintained after 20 day). Moreover, this biosensor exhibits high analytical performance with a wide line arranges (10-17 M âˆ¼ 10-12 M) in buffer, even in 100% goat serum. In both cases, a low limit of detection (LOD) of 3.3 aM(S/N = 3)is showed. To our knowledge, a few examples reported the application of electrochemical biosensors to the direct ultrahigh sensitive determination of MO, especially in whole serum.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas / Mycoplasma Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas / Mycoplasma Idioma: En Ano de publicação: 2020 Tipo de documento: Article