Your browser doesn't support javascript.
loading
Florescence Imaging Lung Cancer with a Small Molecule MHI-148.
Xia, Xiaotian; Gai, Yongkang; Feng, Hongyan; Qin, Chunxia; Pan, Dongfeng; Song, Yiling; Zhang, Yongxue; Lan, Xiaoli.
Afiliação
  • Xia X; Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277 Jiefang Ave, Wuhan, 430022, Hubei Province, China.
  • Gai Y; Hubei Province Key Laboratory of Molecular Imaging, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
  • Feng H; Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277 Jiefang Ave, Wuhan, 430022, Hubei Province, China.
  • Qin C; Hubei Province Key Laboratory of Molecular Imaging, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
  • Pan D; Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277 Jiefang Ave, Wuhan, 430022, Hubei Province, China.
  • Song Y; Hubei Province Key Laboratory of Molecular Imaging, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
  • Zhang Y; Department of Nuclear Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277 Jiefang Ave, Wuhan, 430022, Hubei Province, China.
  • Lan X; Hubei Province Key Laboratory of Molecular Imaging, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
J Fluoresc ; 30(6): 1523-1530, 2020 Dec.
Article em En | MEDLINE | ID: mdl-32780263
ABSTRACT
MHI-148 is a type of heptamethine cyanine dye that can cross the cytoplasmic membrane of lung cancer cells. Here we tested the cytotoxic, in vivo imaging of MHI-148 in lung-cancer nude mice model. Ex vivo imaging was also been measured by testing the major tissue fluorescence intensity. And, the small molecular compound MHI-148 had low cytotoxicity which could be visualized at 1 h post-injection in tumor. From ex vivo fluorescence imaging, the tumor showed the highest uptake of MHI-148 among all the selected organs expect for the time point of 2 h. MHI-148 could be used for effective imaging in lung cancer tissue with good stability and specificity, which suggested that MHI-148 could be an effective tumor clinical imaging agent.