Your browser doesn't support javascript.
loading
Planar and Twisted Molecular Structure Leads to the High Brightness of Semiconducting Polymer Nanoparticles for NIR-IIa Fluorescence Imaging.
Liu, Shunjie; Ou, Hanlin; Li, Yuanyuan; Zhang, Haoke; Liu, Junkai; Lu, Xuefeng; Kwok, Ryan T K; Lam, Jacky W Y; Ding, Dan; Tang, Ben Zhong.
Afiliação
  • Liu S; Department of Chemistry, Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Division of Life Science and State Key Laboratory of Molecular Neuroscience, and Division of Biomedical Engineering, The Hong Kong University of Science and Technology
  • Ou H; State Key Laboratory of Medicinal Chemical Biology, Key Laboratory of Bioactive Materials, Ministry of Education, and College of Life Sciences, Nankai University, Tianjin 300071, China.
  • Li Y; Department of Chemistry, Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Division of Life Science and State Key Laboratory of Molecular Neuroscience, and Division of Biomedical Engineering, The Hong Kong University of Science and Technology
  • Zhang H; Department of Chemistry, Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Division of Life Science and State Key Laboratory of Molecular Neuroscience, and Division of Biomedical Engineering, The Hong Kong University of Science and Technology
  • Liu J; Department of Chemistry, Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Division of Life Science and State Key Laboratory of Molecular Neuroscience, and Division of Biomedical Engineering, The Hong Kong University of Science and Technology
  • Lu X; Department of Chemistry, Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Division of Life Science and State Key Laboratory of Molecular Neuroscience, and Division of Biomedical Engineering, The Hong Kong University of Science and Technology
  • Kwok RTK; Department of Chemistry, Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Division of Life Science and State Key Laboratory of Molecular Neuroscience, and Division of Biomedical Engineering, The Hong Kong University of Science and Technology
  • Lam JWY; Department of Chemistry, Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Division of Life Science and State Key Laboratory of Molecular Neuroscience, and Division of Biomedical Engineering, The Hong Kong University of Science and Technology
  • Ding D; State Key Laboratory of Medicinal Chemical Biology, Key Laboratory of Bioactive Materials, Ministry of Education, and College of Life Sciences, Nankai University, Tianjin 300071, China.
  • Tang BZ; Department of Chemistry, Hong Kong Branch of Chinese National Engineering Research Center for Tissue Restoration and Reconstruction, Division of Life Science and State Key Laboratory of Molecular Neuroscience, and Division of Biomedical Engineering, The Hong Kong University of Science and Technology
J Am Chem Soc ; 142(35): 15146-15156, 2020 09 02.
Article em En | MEDLINE | ID: mdl-32786775
Semiconducting polymer nanoparticles (SPNs) emitting in the second near-infrared window (NIR-II, 1000-1700 nm) are promising materials for deep-tissue optical imaging in mammals, but the brightness is far from satisfactory. Herein, we developed a molecular design strategy to boost the brightness of NIR-II SPNs: structure planarization and twisting. By integration of the strong absorption coefficient inherited from planar π-conjugated units and high solid-state quantum yield (ΦPL) from twisted motifs into one polymer, a rise in brightness was obtained. The resulting pNIR-4 with both twisted and planar structure displayed improved ΦPL and absorption when compared to the planar polymer pNIR-1 and the twisted polymer pNIR-2. Given the emission tail extending into the NIR-IIa region (1300-1400 nm) of the pNIR-4 nanoparticles, NIR-IIa fluorescence imaging of blood vessels with enhanced clarity was observed. Moreover, a pH-responsive poly(ß-amino ester) made pNIR-4 specifically accumulate at tumor sites, allowing NIR-IIa fluorescence image-guided cancer precision resection. This study provides a molecular design strategy for developing highly bright fluorophores.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article