Your browser doesn't support javascript.
loading
Conical Biosilicate Implant for Volume Augmentation in Anophthalmic Sockets.
Brandão, Simone Milani; Schellini, Rodolfo Artioli; Peitl, Oscar; Zanotto, Edgar Dutra; Matayoshi, Suzana; Meneghim, Roberta Lilian Fernandes de Sousa; Schellini, Silvana Artioli.
Afiliação
  • Brandão SM; Division of Medicine, Federal University of Sao Carlos (UFCar), Sao Carlos, São Paulo, Brazil.
  • Schellini RA; Radiology Department of Medical School, State University of Sao Paulo (UNESP), Botucatu, São Paulo, Brazil.
  • Peitl O; Materials Engineering Department, Center for Research, Technology and Education in Vitreous Materials (CeRTEV), Federal University of São Carlos, São Paulo, Brazil.
  • Zanotto ED; Materials Engineering Department, Center for Research, Technology and Education in Vitreous Materials (CeRTEV), Federal University of São Carlos, São Paulo, Brazil.
  • Matayoshi S; Ophthalmology Department of Medical School, University of São Paulo (USP), São Paulo, São Paulo, Brazil.
  • Meneghim RLFS; Ophthalmology Department of Medical School, State University of Sao Paulo (UNESP), Botucatu, São Paulo, Brazil.
  • Schellini SA; Ophthalmology Department of Medical School, State University of Sao Paulo (UNESP), Botucatu, São Paulo, Brazil.
J Craniofac Surg ; 31(6): 1838-1840, 2020 Sep.
Article em En | MEDLINE | ID: mdl-32796301
ABSTRACT
The ideal implant for anophthalmic socket reconstruction has yet to be developed. Biosilicate, a highly bioactive glass-ceramic, has been used in the composition of conical implants, which were initially tested in rabbit orbits with excellent results. However, the use of this material and the conical shape of the implants require further study in the human anophthalmic socket. Thus, we propose the use of a new conical implant composed of Biosilicate for orbital volume augmentation in anophthalmic sockets. This prospective, randomized study included 45 patients receiving conical implants composed of either Biosilicate or polymethylmethacrylate (control). Patients were evaluated clinically before and 7, 30, 60, 120, and 180 days after implantation. Systemic evaluations, laboratory tests, and computed tomography of the orbits were performed preoperatively and 180 days postoperatively. Both groups had good outcomes with no significant infectious or inflammatory processes. Only 1 patient, in the Biosilicate group, had early implant extrusion. Laboratory tests were normal in both groups. Computed tomography scans showed that the implants in both groups were well positioned. The new conical implant composed of Biosilicate was successfully used for anophthalmic socket reconstruction. This implant may provide a good alternative to the only conical implant currently available on the market, which is composed of porous polyethylene.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Orbitárias / Anoftalmia / Implantes Orbitários / Vidro Tipo de estudo: Clinical_trials / Observational_studies Limite: Adolescent / Adult / Aged / Aged80 / Child / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Orbitárias / Anoftalmia / Implantes Orbitários / Vidro Tipo de estudo: Clinical_trials / Observational_studies Limite: Adolescent / Adult / Aged / Aged80 / Child / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article