Your browser doesn't support javascript.
loading
Daratumumab interference in flow cytometric anti-granulocyte antibody testing can be overcome using non-human blocking antibodies.
Baig, Nisar A; Dukek, Brian A; Falbo, Deborah K; Wakefield, Laurie L; DiGuardo, Margaret A; Bobr, Aleh; Kreuter, Justin D; Gandhi, Manish J.
Afiliação
  • Baig NA; Tissue Typing Lab, Transfusion Medicine, Mayo Clinic, Rochester, MN, USA.
  • Dukek BA; Tissue Typing Lab, Transfusion Medicine, Mayo Clinic, Rochester, MN, USA.
  • Falbo DK; Tissue Typing Lab, Transfusion Medicine, Mayo Clinic, Rochester, MN, USA.
  • Wakefield LL; Tissue Typing Lab, Transfusion Medicine, Mayo Clinic, Rochester, MN, USA.
  • DiGuardo MA; Tissue Typing Lab, Transfusion Medicine, Mayo Clinic, Rochester, MN, USA.
  • Bobr A; Tissue Typing Lab, Transfusion Medicine, Mayo Clinic, Rochester, MN, USA.
  • Kreuter JD; Transfusion Lab, University of Nebraska Medical Center, Omaha, NE, USA.
  • Gandhi MJ; Tissue Typing Lab, Transfusion Medicine, Mayo Clinic, Rochester, MN, USA.
Vox Sang ; 116(1): 116-122, 2021 Jan.
Article em En | MEDLINE | ID: mdl-32797679
ABSTRACT

BACKGROUND:

Daratumumab (DARA), a human IgG1K monoclonal antibody targeting CD38, is used to treat refractory multiple myeloma patients. CD38 is expressed on many cell types (RBCs, granulocytes, lymphocytes, etc.), and thus, DARA can interfere with serological tests. Information regarding how DARA affects anti-granulocyte antibody (AGA) testing and optimal neutralization of DARA will help laboratories perform accurate testing.

METHODS:

Screening of AGA was performed by the granulocyte agglutination test (GAT) and the flow cytometric granulocyte immunofluorescence test (Flow-GIFT). Samples were tested from patients on DARA (n = 7), non-transfused blood donors (healthy controls, n = 7) and AGA reactive samples (positive controls, n = 5). Two neutralization experiments, CD38 removal with DTT and DARA epitope blockage with mouse anti-CD38, were evaluated.

RESULTS:

Positive reactivity of human IgG binding was observed in 5/7 DARA cases when tested by Flow-GIFT; however, all 7 cases had negative GAT agglutination results. Further studies by Flow-GIFT revealed DARA concentrations >0·63 µg/ml bound to granulocytes. DARA binding was negated by DTT though a reduced Flow-GIFT sensitivity was observed in positive control samples due to increased background detection of human IgG. Mouse anti-CD38 neutralized the detection of human IgG observed in DARA-treated patient serum without effecting controls.

CONCLUSION:

We established that DARA can interfere with AGA testing, leading to false positive Flow-GIFT results without causing GAT agglutination. DTT treatment increased background binding of secondary antibodies causing a decrease in Flow-GIFT sensitivity. In comparison, blockage of the DARA binding epitope using mouse anti-CD38 antibody was effective in neutralizing DARA interference while maintaining Flow-GIFT sensitivity.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Testes de Aglutinação / Anticorpos Bloqueadores / Citometria de Fluxo / Granulócitos / Anticorpos Monoclonais Limite: Animals / Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Testes de Aglutinação / Anticorpos Bloqueadores / Citometria de Fluxo / Granulócitos / Anticorpos Monoclonais Limite: Animals / Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article