Your browser doesn't support javascript.
loading
Patient-Specific Bicuspid Aortic Valve Biomechanics: A Magnetic Resonance Imaging Integrated Fluid-Structure Interaction Approach.
Emendi, Monica; Sturla, Francesco; Ghosh, Ram P; Bianchi, Matteo; Piatti, Filippo; Pluchinotta, Francesca R; Giese, Daniel; Lombardi, Massimo; Redaelli, Alberto; Bluestein, Danny.
Afiliação
  • Emendi M; Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.
  • Sturla F; Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA.
  • Ghosh RP; 3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Bianchi M; Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA.
  • Piatti F; Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA.
  • Pluchinotta FR; 3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Giese D; Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.
  • Lombardi M; Multimodality Cardiac Imaging, IRCCS Policlinico San Donato, San Donato Milanese, Milan, Italy.
  • Redaelli A; Department of Pediatric and Adult Congenital Heart Disease, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • Bluestein D; Siemens Healthcare GmbH, Erlangen, Germany.
Ann Biomed Eng ; 49(2): 627-641, 2021 Feb.
Article em En | MEDLINE | ID: mdl-32804291
ABSTRACT
Congenital bicuspid aortic valve (BAV) consists of two fused cusps and represents a major risk factor for calcific valvular stenosis. Herein, a fully coupled fluid-structure interaction (FSI) BAV model was developed from patient-specific magnetic resonance imaging (MRI) and compared against in vivo 4-dimensional flow MRI (4D Flow). FSI simulation compared well with 4D Flow, confirming direction and magnitude of the flow jet impinging onto the aortic wall as well as location and extension of secondary flows and vortices developing at systole the systolic flow jet originating from an elliptical 1.6 cm2 orifice reached a peak velocity of 252.2 cm/s, 0.6% lower than 4D Flow, progressively impinging on the ascending aorta convexity. The FSI model predicted a peak flow rate of 22.4 L/min, 6.7% higher than 4D Flow, and provided BAV leaflets mechanical and flow-induced shear stresses, not directly attainable from MRI. At systole, the ventricular side of the non-fused leaflet revealed the highest wall shear stress (WSS) average magnitude, up to 14.6 Pa along the free margin, with WSS progressively decreasing towards the belly. During diastole, the aortic side of the fused leaflet exhibited the highest diastolic maximum principal stress, up to 322 kPa within the attachment region. Systematic comparison with ground-truth non-invasive MRI can improve the computational model ability to reproduce native BAV hemodynamics and biomechanical response more realistically, and shed light on their role in BAV patients' risk for developing complications; this approach may further contribute to the validation of advanced FSI simulations designed to assess BAV biomechanics.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Válvula Aórtica Bicúspide Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Válvula Aórtica Bicúspide Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans Idioma: En Ano de publicação: 2021 Tipo de documento: Article