Your browser doesn't support javascript.
loading
A signal-amplified whole-cell biosensor for sensitive detection of Hg2+ based on Hg2+-enhanced reporter module.
Wang, Dan; Zheng, Yanan; Wei, Liudan; Wei, Na; Fan, Xiaosu; Huang, Shan; Xiao, Qi.
Afiliação
  • Wang D; College of Chemistry and Materials, Guangxi Key Laboratory of Natural Polymer Chemistry and Physics, Nanning Normal University, Nanning 530001, China. Electronic address: wangdan1989323@126.com.
  • Zheng Y; College of Chemistry and Materials, Guangxi Key Laboratory of Natural Polymer Chemistry and Physics, Nanning Normal University, Nanning 530001, China.
  • Wei L; College of Chemistry and Materials, Guangxi Key Laboratory of Natural Polymer Chemistry and Physics, Nanning Normal University, Nanning 530001, China.
  • Wei N; College of Chemistry and Materials, Guangxi Key Laboratory of Natural Polymer Chemistry and Physics, Nanning Normal University, Nanning 530001, China.
  • Fan X; Experimental Center of College of Agriculture, Guangxi University, Nanning 530005, China.
  • Huang S; College of Chemistry and Materials, Guangxi Key Laboratory of Natural Polymer Chemistry and Physics, Nanning Normal University, Nanning 530001, China.
  • Xiao Q; College of Chemistry and Materials, Guangxi Key Laboratory of Natural Polymer Chemistry and Physics, Nanning Normal University, Nanning 530001, China. Electronic address: qi.xiao@whu.edu.cn.
J Environ Sci (China) ; 96: 93-98, 2020 Oct.
Article em En | MEDLINE | ID: mdl-32819703
ABSTRACT
A signal-amplified mercury sensing biosensor with desired sensitivity was developed through firstly using the GFP mutant with fluorescence increasing response towards Hg2+ as the reporter module. The developed biosensor showed response for Hg2+ in a relatively wide range of 1-10,000 nmol/L, and the detection limit was improved one or two orders of magnitude in comparison with most metal-sensing biosensors in similar constructs. In addition, the biosensor could distinguish Hg2+ easily from multiple metal ions and displayed strong adaptability to extensive pH conditions (pH 4.0-10.0). More importantly, the developed biosensor was able to provide an initial assessment of Hg2+ spiked in the environmental water with the recoveries between 85.70% and 112.50%. The signal-amplified strategy performed by the modified reporter module will be widely applicable to many other whole-cell biosensors, meeting the practical requirements with sufficient sensing performance.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Mercúrio Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Mercúrio Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2020 Tipo de documento: Article