Feasibility, Image Quality and Clinical Evaluation of Contrast-Enhanced Breast MRI Performed in a Supine Position Compared to the Standard Prone Position.
Fausto, Alfonso; Fanizzi, Annarita; Volterrani, Luca; Mazzei, Francesco Giuseppe; Calabrese, Claudio; Casella, Donato; Marcasciano, Marco; Massafra, Raffaella; La Forgia, Daniele; Mazzei, Maria Antonietta.
Afiliação
  • Fausto A; Department of Diagnostic Imaging, University Hospital of Siena, Azienda Ospedaliera Universitaria Senese, 53100 Siena, Italy.
  • Fanizzi A; Struttura Semplice Dipartimentale di Fisica Sanitaria, IRCCS Istituto Tumori "Giovanni Paolo II", 70124 Bari, Italy.
  • Volterrani L; Department of Medical, Surgical and Neuro Sciences, Unit of Diagnostic Imaging, University Hospital of Siena, Azienda Ospedaliera Universitaria Senese, 53100 Siena, Italy.
  • Mazzei FG; Department of Diagnostic Imaging, University Hospital of Siena, Azienda Ospedaliera Universitaria Senese, 53100 Siena, Italy.
  • Calabrese C; San Rossore Breast Unit, 56122 Pisa, Italy.
  • Casella D; Department of Oncologic and Reconstructive Breast Surgery, Azienda Ospedaliera Universitaria Senese, University Hospital of Siena, 53100 Siena, Italy.
  • Marcasciano M; Unità di Oncologia Chirurgica Ricostruttiva della Mammella, "Spedali Riuniti" di Livorno, Breast Unit Integrata di Livorno Cecina, Piombino Elba, Azienda USL Toscana Nord Ovest, 57100 Livorno, Italy.
  • Massafra R; Struttura Semplice Dipartimentale di Fisica Sanitaria, IRCCS Istituto Tumori "Giovanni Paolo II", 70124 Bari, Italy.
  • La Forgia D; Struttura Semplice Dipartimentale di Radiologia Senologica, IRCCS Istituto Tumori "Giovanni Paolo II", 70124 Bari, Italy.
  • Mazzei MA; Department of Medical, Surgical and Neuro Sciences, Unit of Diagnostic Imaging, University Hospital of Siena, Azienda Ospedaliera Universitaria Senese, 53100 Siena, Italy.
Cancers (Basel) ; 12(9)2020 Aug 21.
Article em En | MEDLINE | ID: mdl-32825583
ABSTRACT

BACKGROUND:

To assess the feasibility, image quality and diagnostic value of contrast-enhanced breast magnetic resonance imaging (MRI) performed in a supine compared to a prone position.

METHODS:

One hundred and fifty-one patients who had undergone a breast MRI in both the standard prone and supine position were evaluated retrospectively. Two 1.5 T MR scanners were used with the same image resolution, sequences and contrast medium in all examinations. The image quality and the number and dimensions of lesions were assessed by two expert radiologists in an independent and randomized fashion. Two different classification systems were used. Histopathology was the standard of reference.

RESULTS:

Two hundred and forty MRIs from 120 patients were compared. The analysis revealed 134 MRIs with monofocal (U), 68 with multifocal (M) and 38 with multicentric (C) lesions. There was no difference between the image quality and number of lesions in the prone and supine examinations. A significant difference in the lesion extension was observed between the prone and supine position. No significant differences emerged in the classification of the lesions detected in the prone compared to the supine position.

CONCLUSIONS:

It is possible to perform breast MRI in a supine position with the same image quality, resolution and diagnostic value as in a prone position. In the prone position, the lesion dimensions are overestimated with a higher wash-in peak than in the supine position.