Your browser doesn't support javascript.
loading
In situ sampling of tetracycline antibiotics in culture wastewater using diffusive gradients in thin films equipped with graphene nanoplatelets.
You, Nan; Chen, Su; Wang, Yun; Fan, Hong-Tao; Sun, Li-Na; Sun, Ting.
Afiliação
  • You N; College of Chemistry Chemical Engineering and Environmental Engineering, Liaoning Shihua University, Fushun, 113001, Liaoning, China.
  • Chen S; Key Lab of Eco-restoration of Regional Contaminated Environment (Shenyang University), Ministry of Education, Shenyang, 110044, China.
  • Wang Y; College of Sciences, Northeastern University, Shenyang, 110004, China.
  • Fan HT; College of Chemistry Chemical Engineering and Environmental Engineering, Liaoning Shihua University, Fushun, 113001, Liaoning, China. Electronic address: httyf_77@163.com.
  • Sun LN; Key Lab of Eco-restoration of Regional Contaminated Environment (Shenyang University), Ministry of Education, Shenyang, 110044, China. Electronic address: sln629@163.com.
  • Sun T; College of Sciences, Northeastern University, Shenyang, 110004, China. Electronic address: sun1th@163.com.
Environ Res ; 191: 110089, 2020 12.
Article em En | MEDLINE | ID: mdl-32861726
ABSTRACT
A device of graphene nanoplatelet-based diffusion gradients in thin-films (G-DGT) was developed for in situ sampling of tetracycline (TC), oxytetracycline (OTC) and chlortetracycline (CTC) in aquatic environment. The accumulation of antibiotics in a synthetic solution by the proposed G-DGT was consistent with the theoretical curves predicted by the DGT equation. The values of the detection and quantification limits of G-DGT using high-performance liquid chromatography over the deployment time of 7 days were at the level of µg L-1 for the three antibiotics. The performance of the proposed G-DGT was unaffected by pH (3-9) and ionic strength (0.001-0.7 mol L-1 NaNO3). Fulvic acid did not significantly interfere with the performance of the proposed G-DGT device when the mass ratios between the three antibiotics and fulvic acid were within the range of 110-1100. Humic acid had a significant effect on the performance of the proposed G-DGT for the sampling of the three antibiotics due to strong complexation and coprecipitation between the antibiotics and humic acid. The proposed G-DGT was used for the in situ sampling in spiked freshwaters and livestock culture wastewater and exhibited good precision and accuracy without notable interference from the matrices.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Grafite Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Grafite Idioma: En Ano de publicação: 2020 Tipo de documento: Article