Reducing Unnecessary Biopsy of American College of Radiology Thyroid Imaging Reporting and Data System Category 4 Nodules.
Xu, Lei; Zhou, Yibo; Li, Yingru; Lu, Bin; Liu, Tian.
Afiliação
  • Xu L; Department of Ultrasound, Jinhua Hospital of Zhejiang University, Jinhua, China.
  • Zhou Y; Department of Ultrasound, Jinhua Hospital of Zhejiang University, Jinhua, China.
  • Li Y; Department of Ultrasound, Jinhua Hospital of Zhejiang University, Jinhua, China.
  • Lu B; Department of Ultrasound, Jinhua Hospital of Zhejiang University, Jinhua, China.
  • Liu T; Department of Ultrasound, Jinhua Hospital of Zhejiang University, Jinhua, China.
J Ultrasound Med ; 40(2): 227-236, 2021 Feb.
Article em En | MEDLINE | ID: mdl-32870530
ABSTRACT

OBJECTIVES:

To assess the effectiveness of strain elastography (SE), Virtual Touch tissue imaging and quantification (VTIQ; Siemens Medical Solutions, Mountain View, CA) and their combination (SE + VTIQ) in distinguishing benign from malignant American College of Radiology Thyroid Imaging Reporting and Data System category 4 nodules (TR4) to reduce unnecessary biopsy.

METHODS:

In this retrospective study, 985 thyroid nodules from 920 patients were initially enrolled and examined with conventional ultrasound, SE, and VTIQ. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of SE, VTIQ, and SE + VTIQ were calculated respectively. An area under the receiver operating characteristic curve analysis was applied to evaluate the diagnostic efficiency of SE, VTIQ, and SE + VTIQ in the differentiation of benign and malignant TR4 nodules.

RESULTS:

A total of 864 patients with 922 TR4 nodules were enrolled ultimately, as 63 thyroid nodules from 56 patients were excluded because they did not meet the inclusion criteria of this study. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of SE, VTIQ, and SE + VTIQ were 72.4% versus 86.3% versus 82.1%, 77.7% versus 80.5% versus 83.5%, 70.6% versus 76.1% versus 80.2%, 73.4% versus 76.3% versus 83.5%, and 75.5% versus 79.7% versus 82.8%, respectively. The areas under the receiver operating characteristic curve for the diagnosis of TR4 nodules by SE, VTIQ, and SE + VTIQ were 0.751, 0.817, and 0.844.

CONCLUSIONS:

In spite of a slight decrease in the sensitivity, the application of combining SE and VTIQ techniques can improve the specificity and accuracy of TR4 nodule diagnosis, which can help reduce unnecessary biopsies of TR4 nodules.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiologia / Nódulo da Glândula Tireoide / Técnicas de Imagem por Elasticidade Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans País/Região como assunto: America do norte Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiologia / Nódulo da Glândula Tireoide / Técnicas de Imagem por Elasticidade Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans País/Região como assunto: America do norte Idioma: En Ano de publicação: 2021 Tipo de documento: Article