Your browser doesn't support javascript.
loading
Water safety screening via multiplex LAMP-Au-nanoprobe integrated approach.
Oliveira, Beatriz B; Veigas, Bruno; Carlos, Fábio Ferreira; Sánchez-Melsió, Alexandre; Balcázar, José Luís; Borrego, Carles M; Baptista, Pedro Viana.
Afiliação
  • Oliveira BB; UCIBIO, Departamento de Ciências da Vida, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, Campus de Caparica, 2829-516 Caparica, Portugal.
  • Veigas B; UCIBIO, Departamento de Ciências da Vida, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, Campus de Caparica, 2829-516 Caparica, Portugal; i3N|CENIMAT, Departamento de Ciência dos Materiais, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, Campus de Caparica, 2829-51
  • Carlos FF; UCIBIO, Departamento de Ciências da Vida, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, Campus de Caparica, 2829-516 Caparica, Portugal.
  • Sánchez-Melsió A; Catalan Institute for Water Research (ICRA), H2O Building, Scientific and Technological Park of the University of Girona, Emili Grahit 101, E-17003 Girona, (Spain).
  • Balcázar JL; Catalan Institute for Water Research (ICRA), H2O Building, Scientific and Technological Park of the University of Girona, Emili Grahit 101, E-17003 Girona, (Spain).
  • Borrego CM; Catalan Institute for Water Research (ICRA), H2O Building, Scientific and Technological Park of the University of Girona, Emili Grahit 101, E-17003 Girona, (Spain); Group of Molecular Microbial Ecology, Institute of Aquatic Ecology, University of Girona, M. Aurèlia Capmany 40, E-17003, Girona, (Spai
  • Baptista PV; UCIBIO, Departamento de Ciências da Vida, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, Campus de Caparica, 2829-516 Caparica, Portugal. Electronic address: pmvb@fct.unl.pt.
Sci Total Environ ; 741: 140447, 2020 Nov 01.
Article em En | MEDLINE | ID: mdl-32887010
ABSTRACT
Contaminated water resources remain a major global concern regarding public health. The majority of water safety protocols include indicators of microbial contamination to evaluate the potential risk to public health and are key elements of quality guidelines. Among these, markers for total coliforms and fecal coliforms are strong indicators of co-contamination with other pathogens. Traditional methods, recurring to slow and cumbersome culture-based approaches, have been gradually replaced by molecular methods, capable of faster and more specific screening. These are usually PCR-based methods that may allow for multiple pathogen detection but require dedicated laboratory equipment, hindering the rapid on-site assessment. Here, we used a multiplex Loop-Mediated Isothermal Amplification (mLAMP) strategy for the amplification of two markers associated with the contamination by total and fecal coliforms (e.g. Escherichia coli) - lacZ and uidA genes, respectively - thus allowing for single tube multiplex detection. The mLAMP products were then subject to an Au-nanoprobe colorimetric detection assay for precise discrimination of targets. This approach was validated in 22 water samples that were also screened for the presence of lacZ and uidA using standard and quantitative PCR, with the capability for discriminating the contamination level, e.g. a semi-quantitative evaluation of water quality.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas de Amplificação de Ácido Nucleico / Escherichia coli Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas de Amplificação de Ácido Nucleico / Escherichia coli Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Ano de publicação: 2020 Tipo de documento: Article