Your browser doesn't support javascript.
loading
Visual upconversion nanoparticle-based immunochromatographic assay for the semi-quantitative detection of sibutramine.
Zhang, Shi-Wei; Sun, Yan-Yan; Sun, Yuan-Ming; Wang, Hong; Li, Zhen-Feng; Xu, Zhen-Lin.
Afiliação
  • Zhang SW; Guangdong Provincial Key Laboratory of Food Quality and Safety/Guangdong Laboratory of Lingnan Modern Agriculture, South China Agricultural University, Guangzhou, 510642, Guangdong, China.
  • Sun YY; National Nutrition Food Testing Center, Shenzhen Academy of Metrology and Quality Inspection, Shenzhen, 518055, Guangdong, China.
  • Sun YM; Department of Anaesthesiology, Shenzhen University General Hospital, Shenzhen, 518055, Guangdong, China. yysun@szu.edu.cn.
  • Wang H; Guangdong Provincial Key Laboratory of Food Quality and Safety/Guangdong Laboratory of Lingnan Modern Agriculture, South China Agricultural University, Guangzhou, 510642, Guangdong, China.
  • Li ZF; Guangdong Provincial Key Laboratory of Food Quality and Safety/Guangdong Laboratory of Lingnan Modern Agriculture, South China Agricultural University, Guangzhou, 510642, Guangdong, China.
  • Xu ZL; Department of Entomology and Nematology and UCD Comprehensive Cancer Center, University of California Davis, Davis, CA, 95616, USA.
Anal Bioanal Chem ; 412(29): 8135-8144, 2020 Nov.
Article em En | MEDLINE | ID: mdl-32914397
Immunochromatographic assay (ICA) has been used widely for the onsite monitoring of illegal additives due to its simplicity, speed, and low cost. However, a scanner is commonly required for ICA to achieve quantitative results. In this work, we developed a visual semi-quantitative ICA for sibutramine, a banned additive in diet foods, without the need for a scanner for measurement. Monoclonal antibodies specific for sibutramine were raised and conjugated with upconversion nanoparticles (UCNPs) as the luminescent tracer. ICA was developed by employing multiple test lines to achieve the semi-quantitative detection of sibutramine. Based on the optimal conditions, the cutoff levels (limit of quantitation, LOQ) of T1 line, T2 line, T3 line, and T4 line were 0.02 µg/mL, 0.15 µg/mL, 1.0 µg/mL, and 7.5 µg/mL, respectively, in buffer system. The ICA demonstrated a LOQ at 0.2 mg/kg for sibutramine in diet food samples. The assay (including pretreatment) can be finished within 30 min without the aid of other instruments, except a laser pen. No false positive or false negative results were observed. The results indicated that the proposed method was reliable, simple, and rapid for the screening of sibutramine abuse in diet food samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Depressores do Apetite / Cromatografia de Afinidade / Ciclobutanos / Nanopartículas Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Depressores do Apetite / Cromatografia de Afinidade / Ciclobutanos / Nanopartículas Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2020 Tipo de documento: Article