Your browser doesn't support javascript.
loading
A novel Q-value-based nomogram for single intracorneal ring segment implantation versus standard manufacturer's nomogram combined with accelerated cross-linking for treatment of keratoconus: a randomized controlled trial.
Iqbal, Mohammed; Elmassry, Ahmed; Mounir, Amr; Ibrahim, Ola; Soliman, Ashraf.
Afiliação
  • Iqbal M; Department of Ophthalmology, Faculty of Medicine, Sohag University, Sohag, Egypt.
  • Elmassry A; Department of Ophthalmology, Faculty of Medicine, Alexandria University, Alexandria, Egypt.
  • Mounir A; Department of Ophthalmology, Faculty of Medicine, Sohag University, Sohag, Egypt.
  • Ibrahim O; Department of Ophthalmology, Faculty of Medicine, Ain Shams University, Cairo, Egypt.
  • Soliman A; Department of Ophthalmology, Faculty of Medicine, Ain Shams University, Cairo, Egypt.
Acta Ophthalmol ; 99(4): e501-e511, 2021 Jun.
Article em En | MEDLINE | ID: mdl-32930519
PURPOSE: To compare the efficacy of implanting a single Keraring segment according to a novel Q-value-based nomogram (QN) to that of segment implantation according to the manufacturer's standard nomogram (SN), for keratoconus treatment. METHODS: This was a prospective, randomized controlled trial of 104 patients (104 eyes) with Amsler-Krumeich grade 1 or 2 keratoconus, and type 1 or 2 cone asymmetry determined according to manufacturer's classification. They were randomly distributed into two groups: group A patients (n = 52) underwent Keraring implantation according to the SN, and group B patients (n = 52) underwent implantation of a single (210° arc-length) Keraring segment according to the QN. Both treatments were combined with accelerated transepithelial cross-linking, and follow-up was 6 months. Main outcome measures were preoperative and postoperative visual acuity, subjective refraction and corneal topography. RESULTS: At postoperative month 6, group B exhibited statistically significantly higher values of mean uncorrected distance visual acuity (UDVA), sphere, K2, K-average, K-max and Q-anterior (p = 0.02, 0.01, 0.002, 0.001, 0.0001 and 0.03, respectively) compared to that of group A. However, group A exhibited better refractive cylindrical improvements (p = 0.04). In group A, we documented spontaneous extrusion of one Keraring segment. CONCLUSION: Single 210° arc-length segment implantation using our objective QN was more efficacious for keratoconus treatment than using the subjective SN. The nomograms were comparable when the Q-anterior value was >-1.00; however, the QN was superior to the SN when the Q-anterior value was ≤-1.00. The QN yielded greater postoperative UDVA and smoother corneal remodelling than did the SN for treatment of grade 1 and 2 keratoconic eyes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fármacos Fotossensibilizantes / Córnea / Implante de Lente Intraocular / Reagentes de Ligações Cruzadas / Nomogramas / Ceratocone / Lentes Intraoculares Tipo de estudo: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fármacos Fotossensibilizantes / Córnea / Implante de Lente Intraocular / Reagentes de Ligações Cruzadas / Nomogramas / Ceratocone / Lentes Intraoculares Tipo de estudo: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article