Your browser doesn't support javascript.
loading
Results and Lessons Learned on Robotic Assisted Kidney Transplantation.
Musquera, Mireia; Peri, Lluis; Ajami, Tarek; Revuelta, Ignacio; Izquierdo, Laura; Mercader, Claudia; Sierra, Alba; Diekmann, Fritz; D'Anna, Maurizio; Monsalve, Concepción; Alcaraz, Antonio.
Afiliação
  • Musquera M; Department of Urology, Hospital Clínic, Barcelona 08036, Spain.
  • Peri L; Department of Urology, Hospital Clínic, Barcelona 08036, Spain.
  • Ajami T; Department of Urology, Hospital Clínic, Barcelona 08036, Spain.
  • Revuelta I; Department of Nephrology and Kidney Transplant, Hospital Clínic, Barcelona 08036, Spain.
  • Izquierdo L; Department of Urology, Hospital Clínic, Barcelona 08036, Spain.
  • Mercader C; Department of Urology, Hospital Clínic, Barcelona 08036, Spain.
  • Sierra A; Department of Urology, Hospital Clínic, Barcelona 08036, Spain.
  • Diekmann F; Department of Nephrology and Kidney Transplant, Hospital Clínic, Barcelona 08036, Spain.
  • D'Anna M; Department of Urology, Hospital Clínic, Barcelona 08036, Spain.
  • Monsalve C; Department of Anesthesiology, Hospital Clínic, Barcelona 08036, Spain.
  • Alcaraz A; Department of Urology, Hospital Clínic, Barcelona 08036, Spain.
Biomed Res Int ; 2020: 8687907, 2020.
Article em En | MEDLINE | ID: mdl-32934965
ABSTRACT

INTRODUCTION:

Nowadays, minimally invasive surgery in kidney transplantation is a reality thanks to robotic assistance. In this paper, we describe our experience, how we developed the robotic assisted Kidney transplantation (RAKT) technique, and analyze our results. Material and Methods. This is a retrospective study of all RAKTs performed at our center between July 2015 and March 2020. We describe the donor selection, surgical technique, and analyze the surgical results and complications. A comparison between the first 20 cases and the following ones is performed.

RESULTS:

During the aforementioned period, 82 living donor RAKTs were performed. The mean age was 47.4 ± 13.4 and 50 (61%) were male. Mean body mass index was 25 ± 4.7 and preemptive in 63.7% of cases. Right kidneys and multiple arteries were seen in 14.6% and 12.2%, respectively. Mean operative and rewarming time was 197 ± 42 and 47 ± 9.6 minutes, respectively. Five cases required conversion to open surgery because of abnormal kidney vascularization. Two patients required embolization for subcapsular and hypogastric artery bleeding without repercussion. Three kidneys were lost, two of them due to acute rejection and one because venous thrombosis. Late complications requiring surgery included one kidney artery stenosis, one ureteral stenosis, two lymphoceles, and three hernia repairs. We noticed a significant reduction in time between the first 20 cases and the following ones from 248.25 ± 38.1 to 189.75 ± 25.3 (p < 0.05). With a mean follow-up time of 1.8 years (SD 1.3), the mean creatinine was 1.52 (SD 0.7) and RAKT graft survival was 98%.

CONCLUSIONS:

The robotic approach is an attractive, minimally invasive method for kidney transplantation, yielding good results. Further studies are needed to consider it a standard approach.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transplante de Rim / Procedimentos Cirúrgicos Robóticos / Sobrevivência de Enxerto / Rim Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transplante de Rim / Procedimentos Cirúrgicos Robóticos / Sobrevivência de Enxerto / Rim Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article