Your browser doesn't support javascript.
loading
Evaluation of nucleus pulposus fluid velocity and pressure alteration induced by cartilage endplate sclerosis using a poro-elastic finite element analysis.
Hassan, Chaudhry Raza; Lee, Wonsae; Komatsu, David Edward; Qin, Yi-Xian.
Afiliação
  • Hassan CR; Department of Biomedical Engineering, Stony Brook University, 215 Bioengineering Building, Stony Brook, NY, 11794, USA.
  • Lee W; Department of Biomedical Engineering, Stony Brook University, 215 Bioengineering Building, Stony Brook, NY, 11794, USA.
  • Komatsu DE; Department of Orthopaedics, School of Medicine, Stony Brook University, Stony Brook, NY, USA.
  • Qin YX; Department of Biomedical Engineering, Stony Brook University, 215 Bioengineering Building, Stony Brook, NY, 11794, USA. yi-xian.qin@stonybrook.edu.
Biomech Model Mechanobiol ; 20(1): 281-291, 2021 Feb.
Article em En | MEDLINE | ID: mdl-32949306
ABSTRACT
The nucleus pulposus (NP) in the intervertebral disk (IVD) depends on diffusive fluid transport for nutrients through the cartilage endplate (CEP). Disruption in fluid exchange of the NP is considered a cause of IVD degeneration. Furthermore, CEP calcification and sclerosis are hypothesized to restrict fluid flow between the NP and CEP by decreasing permeability and porosity of the CEP matrix. We performed a finite element analysis of an L3-L4 lumbar functional spine unit with poro-elastic constitutive equations. The aim of the study was to predict changes in the solid and fluid parameters of the IVD and CEP under structural changes in CEP. A compressive load of 500 N was applied followed by a 10 Nm moment in extension, flexion, lateral bending, and axial rotation to the L3-L4 model with fully saturated IVD, CEP, and cancellous bone. A healthy case of L3-L4 physiology was then compared to two cases of CEP sclerosis a calcified cartilage endplate and a fluid constricted sclerotic cartilage endplate. Predicted NP fluid velocity increased for the calcified CEP and decreased for the calcified + less permeable CEP. Decreased NP fluid velocity was prominent in the axial direction through the CEP due to a less permeable path available for fluid flux. Fluid pressure and maximum principal stress in the NP were predicted to increase in both cases of CEP sclerosis compared to the healthy case. The porous medium predictions of this analysis agree with the hypothesis that CEP sclerosis decreases fluid flow out of the NP, builds up fluid pressure in the NP, and increases the stress concentrations in the NP solid matrix.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reologia / Esclerose / Cartilagem / Análise de Elementos Finitos / Elasticidade / Núcleo Pulposo Tipo de estudo: Prognostic_studies Limite: Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reologia / Esclerose / Cartilagem / Análise de Elementos Finitos / Elasticidade / Núcleo Pulposo Tipo de estudo: Prognostic_studies Limite: Humans / Male / Middle aged Idioma: En Ano de publicação: 2021 Tipo de documento: Article