Your browser doesn't support javascript.
loading
Validation of the clinical applicability of knowledge-based planning models in single-isocenter volumetric-modulated arc therapy for multiple brain metastases.
Kishi, Noriko; Nakamura, Mitsuhiro; Hirashima, Hideaki; Mukumoto, Nobutaka; Takehana, Keiichi; Uto, Megumi; Matsuo, Yukinori; Mizowaki, Takashi.
Afiliação
  • Kishi N; Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
  • Nakamura M; Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
  • Hirashima H; Department of Information Technology and Medical Engineering, Division of Medical Physics, Graduate School of Medicine, Human Health Sciences, Kyoto University, Kyoto, Japan.
  • Mukumoto N; Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
  • Takehana K; Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
  • Uto M; Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
  • Matsuo Y; Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
  • Mizowaki T; Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
J Appl Clin Med Phys ; 21(10): 141-150, 2020 Oct.
Article em En | MEDLINE | ID: mdl-32951337
PURPOSE: To validate the clinical applicability of knowledge-based (KB) planning in single-isocenter volumetric-modulated arc therapy (VMAT) for multiple brain metastases using the k-fold cross-validation (CV) method. METHODS: This study comprised 60 consecutive patients with multiple brain metastases treated with single-isocenter VMAT (28 Gy in five fractions). The patients were divided randomly into five groups (Groups 1-5). The data of Groups 1-4 were used as the training and validation dataset and those of Group 5 were used as the testing dataset. Four KB models were created from three of the training and validation datasets and then applied to the remaining Groups as the fourfold CV phase. As the testing phase, the final KB model was applied to Group 5 and the dose distributions were calculated with a single optimization process. The dose-volume indices (DVIs), modified Ian Paddick Conformity Index (mIPCI), modulation complexity scores for VMAT plans (MCSv), and the total number of monitor units (MUs) of the final KB plan were compared to those of the clinical plan (CL) using a paired Wilcoxon signed-rank test. RESULTS: In the fourfold CV phase, no significant differences were observed in the DVIs among the four KB plans (KBPs). In the testing phase, the final KB plan was statistically equivalent to the CL, except for planning target volumes (PTVs) D2% and D50% . The differences between the CL and KBP in terms of the PTV D99.5% , normal brain, and Dmax to all organs at risk (OARs) were not significant. The KBP achieved a lower total number of MUs and higher MCSv than the CL with no significant difference. CONCLUSIONS: We demonstrated that a KB model in a single-isocenter VMAT for multiple brain metastases was equivalent in dose distribution, MCSv, and total number of MUs to a CL with a single optimization.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Encefálicas / Radiocirurgia / Radioterapia de Intensidade Modulada Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Encefálicas / Radiocirurgia / Radioterapia de Intensidade Modulada Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article